HUIRUIPU HRP-K2000-2 Two-Channel Gas Alarm Controller

SE
4-20mA three-wire system, standard with two Detectors, digital cycle display, button operation, with two-level alarm, wall-mounted installation, support indicator light and sound and light dual alarm.
$134.00/set
PromotionLoading...
Coupon
Model:
Certificate

HuiRuiPu HRP-K2000-2 Gas alarm controllerSPEC

HuiRuiPu HRP-K2000-2 Gas alarm controllerDetails

HuiRuiPu HRP-K2000-2 Gas alarm controllerPacking list

SKU
NB044039
Display
Large LED digital display
Operation mode
key operation
Operating Voltage
AC220V±10% 50HZ
backup Power
24V 0.8AH lead-acid battery (optional)
switch output
2 sets of passive relay output, touchpoint Capacity 10A/AC220V
System Power
Maximum power consumption 10W (without external devices)
Number of Detectors
2
Detector connection
4-20mA signal
data upload
Modbus-RTU protocol (optional)
alarm point
Two-level alarm, can be freely set by the user
Alarm indication
Indicator light + sound and light double alarm
Operating Mode
On-site fixed installation, wall hanging
wiring specification
3 wires need to be connected. It is recommended to use ≥ RVVP2 * 1.5 national standard Shielding wire, the diameter of the single core wire is ≥ 1.5mm, and the wire length is ≤ 1000m.
HRP-K2000-2
Gas alarm controller
4-20mA three-wire system, standard with two Detectors, digital cycle display, button operation, with two-level alarm, wall-mounted installation, support indicator light and sound and light dual alarm.
HUIRUIPU HRP-K2000-2 Two-Channel Gas Alarm Controller Picture

Introduction

Two-channel split-line gas detection and alarm controller is used to detect the content of flammable gas or toxic gas in the air, supports two-channel 4-20mA signal input, and centrally controls multiple points at the same time. The system adopts a microprocessor as the Control Unit. When the concentration of flammable gas in the environment reaches or exceeds the preset value, the controller immediately emits sound and light alarms, and can drive exhaust or other peripheral actions through relays to prevent explosions and fire accidents, thereby safeguarding life. The system can be widely used in factories, oil depots, liquefied gas stations, gas stations, gas stations, paint spray rooms and other places that need fire prevention and explosion-proof, for safety monitoring and alarming.

Operation panel and key instructions

HUIRUIPU HRP-K2000-2 two-channel gas alarm controller Figure 1


[Settings] key: enter the menu or confirm the function

[Up] key: up or increase

[Down] key: down or reduce

[Exit] key: return or exit, it is also the [muffler] function when static.

Indicator light: [1] indicates the first channel; [2] indicates the second channel; the green light indicates the normal state, and the red light indicates the alarm state.

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.