CHINA CHP-160Q Co2 Incubator 160L/700W

SE
Volume 160L, humidity control range RT + 5~ 60 ℃, Temperature Fluctuation +/- 0.5 ℃, Temperature uniformity +/- 1 ℃, temperature recovery time ≤ 15 minutes (37 ℃), carbon dioxide control range 0-20% V/V, carbon dioxide concentration recovery time concentration value × 1.2 minutes
$1992.00/set
PromotionLoading...
Coupon
Model:

Factory CHP-160Q Co2 IncubatorSPEC

Factory CHP-160Q Co2 IncubatorDetails

Factory CHP-160Q Co2 IncubatorPacking list

SKU
NB044435
Volume
160L
Humidity control range
RT+5~60℃
Temperature Fluctuation
±0.5℃
Temperature Uniformity
±1℃
temperature recovery time
≤ 15 minutes (at 37 ℃)
Carbon dioxide control range
0-20%V/V
Carbon dioxide concentration recovery time
Concentration value × 1.2 minutes
Power
220V 50HZ
Power
≤700W
Ambient Temperature
5~35℃
Liner size
500*500*650mm
Dimensions
650×610×990
Heating method
natural evaporation
Heating mode
Air sleeve
Relative Humidity
≤85%RH
CHP-160Q
Co2 Incubator
Volume 160L, humidity control range RT + 5~ 60 ℃, Temperature Fluctuation +/- 0.5 ℃, Temperature uniformity +/- 1 ℃, temperature recovery time ≤ 15 minutes (37 ℃), carbon dioxide control range 0-20% V/V, carbon dioxide concentration recovery time concentration value × 1.2 minutes
CHINA CHP-160Q Co2 Incubator 160L/700W Picture

Equipment introduction

   The new generation CHP series carbon dioxide Incubator is a high-performance carbon dioxide Incubator developed by the company's many years of technical experience and the introduction of new processes. It has the characteristics of fast heating and small temperature fluctuation: it is ideal for carrying out immunology, oncology, genetics and biology. The key equipment necessary for engineering is widely used in the research and production of medicine, microbiology, agricultural science, and pharmacology.

This machine is a desktop carbon dioxide Incubator, which is composed of a plastic spray shell, a stainless steel working chamber and an electronic control part. A carbon dioxide cylinder and a carbon dioxide pressure reducing valve must be available during use. The carbon dioxide gas must be pure and the pressure of the pressure reducing valve must be stable. The carbon dioxide cylinder is a pressure volume and is prepared by the user. The pressure reducing valve is a special pressure reducing valve for carbon dioxide. Its performance directly affects the accuracy of the carbon dioxide concentration in the tank, so it is matched by our company.

Features

1. The CO2 Incubator has two heating methods: water jacket type and air jacket type, which can heat up quickly and have good uniformity.

2. The temperature sensor is Pt100 platinum resistor, which has good interchangeability.

3. The temperature control circuit uses two sensors: alarm and main control box temperature. Even if the main control circuit is out of control, the alarm circuit can still limit the temperature, greatly improving reliability.

4. The carbon dioxide input loop is uniquely designed and can be quickly restored after opening the door (for example: when the concentration is 5%, the recovery time does not exceed 6 minutes, and when the concentration is 10%, the recovery time does not exceed 12 minutes). The carbon dioxide concentration is input by the ratio of air and carbon dioxide. The concentration Not affected by humidity, etc.

5. The humidity is natural evaporation.

6. It adopts a double door structure, the outer door adopts a magnetic door seal structure, and the inner chamber glass door and box adopt silicone rubber sealing strips, which has good sealing performance, avoids contamination and facilitates observation.

FAQ
QOur laboratory mainly does cell fostering, and needs a stable temperature and carbon dioxide environment. Is your CHP-160Q Co2 incubator suitable?
A Suitable! CHP-160Q uses air sleeve heating, the temperature is fast and uniform, and the temperature fluctuation is only +/- 0.5 ° C, which can ensure the stability of the cell foster environment. Its carbon dioxide concentration recovers particularly quickly, and the 5% concentration can be restored in 6 minutes after opening the door, which is very suitable for cell foster operations with frequent lofting.