HANNA HI98127 pH Measurement Instrument - 2.0~16.0pH

SE
Measurement range -2.0 to 16.0pH; -5.0 to 60.0 ℃ (23.0 to 140.0 ° F), resolution 0.1pH; 0.1 ℃, 0.1 ° F, waterproof design, large screen LCD, automatic temperature compensation, suitable for laboratory level or outdoor environment measurement.
$257.00/set
PromotionLoading...
Coupon
Model:

HANNA HI98127 Acidity meterSPEC

HANNA HI98127 Acidity meterDetails

HANNA HI98127 Acidity meterPacking list

SKU
NB045242
Measurement range
-2.0 to 16.0pH; -5.0 to 60.0℃ (23.0 to 140.0℉)
resolution
0.1pH;0.1℃、0.1℉
Measurement Accuracy
±0.1pH;±0.5℃、±1℉
Acidity -pH calibrated
Automatic 1 and 2 point calibrating, built-in 2 sets of calibrating points (pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18)
Temperature compensation
Automatic temperature compensation
Operating Environment
-5.0 to 50.0℃(23.0 to 140.0℉)
Size/Weight
163*40*26mm/100g
Electrode type
Customized in-line pH replaceable Glass electrode (HI73128 customized special electrode replacement tool is required)
HI98127
Acidity meter
Measurement range -2.0 to 16.0pH; -5.0 to 60.0 ℃ (23.0 to 140.0 ° F), resolution 0.1pH; 0.1 ℃, 0.1 ° F, waterproof design, large screen LCD, automatic temperature compensation, suitable for laboratory level or outdoor environment measurement.
HANNA HI98127 pH Measurement Instrument - 2.0~16.0pH Picture

Introduction

HI98127 acidity pH meter measuring range: -2.0 to 16.0 pH, accuracy: ±0.1pH; suitable for on-site or laboratory use, easy and affordable operation, and meets laboratory measurement standards.

It has functions such as large-screen LCD, automatic identification and calibration, measurement value identification, automatic shutdown, etc., humanized operation interface, stable indication mark, two-button simple operation, convenient operation, automatic identification and calibration of 1-2 points of acidity, and built-in 2 sets of acidity standards. Calibration points and automatic temperature compensation ensure measurement accuracy and accuracy in different environments. Battery display and automatic shutdown. When the battery is insufficient, a low battery symbol is displayed to prompt timely replacement of the battery. The instrument can be set to automatically shut down in 8 minutes, which is suitable for Laboratory-grade measurement results are also available in the field.

Features

  • Waterproof design, large screen LCD, replaceable probe design

  • Humanized operation interface, stable indication marks, two-button simple operation, convenient operation

  • Automatic identification and calibration, built-in 2 sets of acidity calibration points

  • Automatic temperature compensation

  • BEPS low-battery error-proofing system, low-battery display sign, 8-minute automatic shutdown function can be set

  • Suitable for measurements at laboratory level or outdoor environments

FAQ
QI want to test the alkalinity of fish tank water, is this HI98127 acidity meter suitable?
A Perfect fit. The HI98127 is easy to operate and has a two-button design that makes it easy to operate at home. It is waterproof, suitable for use next to fish tanks, and automatic temperature compensation ensures accurate measurements at different water temperatures, allowing you to keep track of water quality at all times, which is important for fish health.
QI need to go outdoors often to measure the pH value of the soil. Is this instrument functional enough?
A Sufficient. HI98127 is designed to be rugged and suitable for outdoor environments. It has a low battery prompt and automatic shutdown function, so you don't have to worry about field power problems. Measurement range is wide (-2.0 to 16.0pH), resolution is 0.1, can deal with a variety of soil acid alkalinity conditions, providing reliable field data.
QHow to deal with the effect of high or low sample concentration on Conductivity Meter measurement?
A Too high or too low a sample concentration may exceed the Measurement range of the Conductivity Meter or affect Measurement accuracy. It is recommended to dilute or condense the sample appropriately to ensure measurement within the applicable range of the Conductivity Meter.
Standard