HANNA HI6321 Desktop conductivity Tester

SE
A 7-inch capacitive touchscreen that supports multi-touch, stores a minimum of 1,000,000 data points per user, and friendly icons and symbols allow users to easily navigate and interpret instrument functions.
Model:

HANNA HI6321 Desktop Conductivity MeterSPEC

HANNA HI6321 Desktop Conductivity MeterDetails

HANNA HI6321 Desktop Conductivity MeterPacking list

SKU
NB045243
Resolution - conductivity EC
0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm
Measurement range - Electrical resistivity
1.0~99.9 Ω•cm; 100~999 Ω•cm; 1.00~9.99 KΩ•cm; 10.0~99.9 KΩ•cm; 100~999 KΩ•cm; 1.00~9.99 MΩ•cm; 10.0~100.0 MΩ•cm
Resolution - Electrical resistivity
0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm
Measurement Accuracy - Electrical resistivity
+/- 1 % ( +/- 1Ω • cm) of reading
TDS range
0.000~9.999 ppm, 10.00~99.99 ppm, 100.0~999.9 ppm, 1.000~9.999 ppt, 10.00~99.99 ppt, 100.0~400.0 ppt (conversion factor 1.00)
Resolution-TDS
0.001 ppm, 0.01 ppm, 0.1 ppm, 0.001 ppt, 0.01 ppt, 0.1 pp
Measurement Accuracy - TDS
+/- 1 % ( +/- 0.01 ppm) of reading
Measurement range - salinity
Actual salinity: 0.00~42.00 psu; Seawater salinity: 0.00~80.00 ppt; salinity percentage: 0.0~400.0%
Resolution - salinity
0.01 (actual salinity, seawater salinity); 0.1% salinity
Measurement Accuracy - salinity
+/- 1% of reading
Measurement range - temperature
-20.0~120.0˚C
Resolution - Temperature
0.1 °C
Measurement Accuracy - temperature
±0.2 °C
Calibrated point
Automatic recommendation/user customization
Standard calibrating fluid
84.00μS/cm,1.413mS/cm,5.000mS/cm,12.88mS/cm,80.00mS/cm,111.8mS/cm
Reminder - conductivity calibrated
Turn off function; Daily: 0 minutes to 23 hours 59 minutes; Period: 1 minute to 500 days, 23 hours 59 minutes
Electrical resistivity calibrated
By conductivity calibrated
Salinity calibrated
1 calibrated point (percentage)
Temperature compensation
Automatic compensation or manual
View type
Direct/automatic hold
Stability
Accurate; medium; fast
Sampling rate
1000 ms
Icon (drawing)
The relationship between pH (or mV) and temperature and time can be translated or scaled (Graduation technique).
record type
Automatic, manual recording, automatic maintenance
Number of records
Maximum of 50,000 data points per file; minimum of 1,000,000 data points per user
automatic interval
One, two, five, 10, 30 seconds; one, two, five, 10, 15, 30, 60, 120, 150, 180 minutes.
Sample ID
incremental mode
Export options
.Csv file format
user
Up to 9 users and administrators. Account (default)
USB-A
2 ports for keyboard input or US-A driver
USB-C
1 port for PC connection and USB-C drive
Wi-Fi & Ethernet
FTP; Web server log transfer and download; E-mail
RS232
Connect peripheral devices
Power
DC Adapter 100-240AC, 24 VDC 2.5A
Operating Environment
0 - 50.0 °C
Size/Weight
205 x 160 x 77mm / ≈1.2kg
HI6321
Desktop Conductivity Meter
A 7-inch capacitive touchscreen that supports multi-touch, stores a minimum of 1,000,000 data points per user, and friendly icons and symbols allow users to easily navigate and interpret instrument functions.
HANNA HI6321 Desktop conductivity Tester Picture

Introduction

HI6321 is a streamlined desktop instrument with a large touch screen display, consisting of an instrument housing and an integrated conductivity measurement module. The HI6321 is compact and easy to operate and includes Hanna's HI7631233 four-ring conductivity/resistivity/TDS/salinity probe.

Recommended for use in a wide range of industrial process water applications, the HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibration. An integrated temperature sensor measures the process temperature and adjusts the measured conductivity to the reference temperature by applying a specialized compensation algorithm:

Linear: Applies when the temperature coefficient of variation is assumed to have the same value for all measured temperatures.

Standard: Suitable for high-purity water measurement and documented in ASTM standard D5391-14. This setting applies to resistivity measurements greater than 1Mohm.cm.

Natural: Applicable to natural groundwater, well water or surface water (or water with similar composition) that meets ISO7888 standards.

TDS is a calculated value based on the conductivity of the solution (TDS = coefficient x EC25). The TDS factor is the conversion factor used to change EC measurements to ppm measurements.

Sal psu: The actual salinity of seawater is related to the ratio of the conductivity of a normal seawater sample at 15℃ and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g/Kg at the same temperature and pressure. Under these conditions, the ratio is equal to 1 and S=35. Actual salinity levels are available for values ​​from 0 to 42.00 psu at temperatures from 0 to 35℃.

Sal ppt: Measurements expressed in ppt are based on natural seawater grades of 0.00 to 80.00 g/L and cover a temperature range of 10 to 31℃. It determines the salinity based on the conductivity of the sample compared to standard seawater at 15℃ and the salinity value in seawater of approximately 35.

Sal%: In this range, 100% salinity is equivalent to approximately 10% solids.

Features

user interface

7-inch capacitive touch screen that supports multi-touch;

capacitive touch screen, home and system menu keys;

User-friendly icons and symbols allow users to easily navigate and explain instrument functions;

Users can choose between five different views:

  • Simple GLP with calibration information.

  • Complete GLP with electrode status and calibration point details.

  • Interactive graphics that update in real time.

  • Tabular data containing date, time and comments.

calibration

Standard single-point salinity calibration of 100% salinity standard, with reading salinity scale set to %;

Standard single or multiple conductivity calibration using standards;

Non-volatile memory saves data and settings.

Record

Data log collection (with time and date stamp) of at least 1,000,000 data points;

Logging type: manual, automatic, automatic retention;

Manually and automatically maintain sample IDs for data.

Connect features and services

Transfer recorded data to USB drive;

Includes log files of measurement and calibration data (as .csv files);

FTP and email for log export via Ethernet and Wi-Fi connections;

USB Type A, for USB flash drives, keyboards and printers;

Type C USB for USB flash drive and PC connection.

Instrument guide help section

Video support demonstration of key features.

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard