Italy

HANNA HI98198 Portable (Fluorescence Method) Dissolved Oxygen DO-Saturated Dissolved Oxygen Meter

SE
Dissolved oxygen DO range: 0.00 to 50.00 mg/L (ppm), saturated dissolved oxygen: 0.0 to 500.0%, dissolved oxygen DO resolution: 0.01 mg/L (ppm), IP68 international waterproof grade, completely sealed waterproof and dustproof.
$2850.00/set
PromotionLoading...
Coupon
Model:

HANNA HI98198 Dissolved Oxygen MeterSPEC

HANNA HI98198 Dissolved Oxygen MeterDetails

HANNA HI98198 Dissolved Oxygen MeterPacking list

SKU
NB045254
Dissolved oxygen DO range
Dissolved oxygen DO: 0.00 to 50.00 mg/L (ppm), saturated dissolved oxygen: 0.0 to 500.0%
DO resolution of dissolved oxygen
Dissolved oxygen DO: 0.01 mg/L (ppm), saturated dissolved oxygen: 0.1%
Dissolved oxygen DO calibrated
Single or two-point calibrating Automatic calibration, 100% (8.26mg/L) auto-calibrating at zero or air; user-defined single-point calibrating
atmospheric pressure range
420 to 850 mmHg
Atmospheric pressure resolution/Accuracy
Resolution: 1mmHg; Accuracy: calibrated point +/- 15% range +/- 3mmHg
Atmospheric pressure calibrated
Manual calibration within atmospheric pressure Measurement Range
Temperature range
-5.0 to 50.0 ℃ (23 to 122 ° F), sensor type; thermistor
Temperature Resolution/Accuracy
+/- Resolution: 0.1 ℃ (0.1 ° F); Accuracy : +/- 0.3 ℃( +/- 0.4 ° F)
Temperature calibrated
Manual calibration within temperature range
Temperature compensation
Automatic compensation temperature -5.0 to 50.0 ℃ (23 to 122.0 ° F)
Salinity compensation
Manual compensation range 0 to 70 PSU
atmospheric pressure compensation
Automatic compensation range 420 to
Data Logging
4000 measurement Data storage
Interface
USB-C Interface, choose HI920016 dedicated USB-C data transmission cable to transfer stored data to the computer, which is convenient for data management and analysis
Standard electrode
HI764113 built-in temperature transducer custom-made Optical inspection fluorescent dissolved Oxygen electrode, specification: 4 meters [Configure HI764113-3 dissolved Oxygen electrode 316 stainless steel protective cover, maximum bearing depth and pressure: 20 meters/29 PSI]
protection standard
Host meets IP67 waterproof international standards; HI764113 Optical inspection Fluorescent dissolved Oxygen electrode meets IP68 waterproof international standards
Voltage type
1.5VAAAx4 high-quality battery, automatic shutdown settings: 5, 10, 30, 60 minutes or disabled
Applicable environment
0 to 50 ℃(32 to 122 ℉)max.RH 100%
HI98198
Dissolved Oxygen Meter
Dissolved oxygen DO range: 0.00 to 50.00 mg/L (ppm), saturated dissolved oxygen: 0.0 to 500.0%, dissolved oxygen DO resolution: 0.01 mg/L (ppm), IP68 international waterproof grade, completely sealed waterproof and dustproof.
HANNA HI98198 Portable (Fluorescence Method) Dissolved Oxygen DO-Saturated Dissolved Oxygen Meter Picture

Introduction

HI98198 uses optical fluorescence (OPDP) measurement method to ensure the accuracy of dissolved oxygen measurement. Through built-in standard methods and standards, it can easily measure dissolved oxygen DO, biochemical oxygen consumption BOD, oxygen consumption rate OUR, and specific oxygen consumption rate SOUR. , no need to perform complex calculations.

HI764113 customized optical fluorescence dissolved oxygen electrode with built-in temperature sensor is suitable for the measurement of dissolved oxygen in fresh water and salt water (or seawater). The solid ABS dissolved oxygen electrode body and HI764113-3 customized HI764113 optical fluorescent dissolved oxygen electrode stainless steel protective cover ensure the durability and reliability of the dissolved oxygen electrode when measuring in various harsh environments. The HI764113 dissolved oxygen electrode meets the IP68 international waterproof rating. Completely sealed against water and dust. Dome cap design can repel air bubbles, improve measurement sensitivity and fast response time, does not require a minimum flow rate, eliminates the trouble of operating problems of dissolved oxygen membrane and dissolved oxygen filling solution, and does not require dissolved oxygen electrode polarization time, HI764113 optical fluorescence dissolved oxygen The electrodes are ready to work when you need them.

Characteristics

  • Data traceability: With a dedicated key, GLP data can be easily queried, including the date, time, pressure, calibration value, temperature and salinity values ​​of the last calibration, ensuring data security.

  • Data logging and management: Allows you to store up to 4000 measurement readings. You can use the [AutoEnd] key to automatically maintain the first stable reading on the display during measurement;

  • Tip function: When you use or replace a new fluorescent dissolved oxygen membrane for the first time, the H198198 Dissolved Oxygen Meter will automatically detect and initialize the dissolved oxygen electrode. When the fluorescent dissolved oxygen membrane is damaged or lost, the instrument will remind you to replace the fluorescent dissolved oxygen membrane and reduce measurement problems caused by problems with the fluorescent dissolved oxygen membrane.

  • Excellent usage characteristics: The protection level host complies with IP67, and the dissolved oxygen electrode complies with the IP68 international waterproof standard, which means that bad weather, splashes and dust will not affect the user’s on-site measurement of dissolved oxygen; the large LCD display and backlight function ensure that you Easily view all measurement information in any lighting condition; the high-quality, rugged body design makes this portable meter suitable for field use.

  • Powerful data management function: The multi-functional USB-C interface has seamless data transmission function. If you purchase the H1920016 dedicated USB AC data transmission cable, no special application software is required, and the stored data can be transferred to a computer, U disk or Android device in .csv format. .

  • Dedicated quick-connect dissolved oxygen electrode: The uniquely designed quick-connect waterproof connector is used to quickly and easily install the dissolved oxygen DO electrode, making the removal and installation of the dissolved oxygen electrode simple and fast.

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard