HANNA HI93703-11 Dual range turbidity Tester

SE
Measurement range 0.00-50. 00FTU, 50-1000FTU, range automatic identification range conversion, resolution 0.01FTU (0.00-50. 00FTU), 1FNU (50-1000FTU), custom 890nm Infrared source, suitable for water quality monitoring, wastewater field and laboratory measurement use.
$1580.00/set
PromotionLoading...
Coupon
Model:

HANNA HI93703-11 Turbidity MeterSPEC

HANNA HI93703-11 Turbidity MeterDetails

HANNA HI93703-11 Turbidity MeterPacking list

SKU
NB045262
Measurement range
0.00-50.00FTU、50-1000FTU
range
Automatic identification range conversion
resolution
0.01FTU(0.00-50.00FTU)、1FNU(50-1000FTU)
Measurement Accuracy
+/- 5% of reading or +/- 0.5 FTU, whichever is greater (@25 ℃)
Calibrated mode
Manual 3-point calibrating, built-in 3 calibrating points; 0FTU, 10FTU, 500FTU
Light source system
Silicon Photocell, photovoltaic cell, custom Infrared source, 890nm
unit conversion
1FTU = 1NTU = 1FNU = 0.25ECB; 1mg / L = 1
Measurement standard
Compliant with ISO7027 turbidity measurement standard
data management
RS232 Interface, 199 measurement Data storage
Automatic shutdown
4X1.5V AA battery; will automatically shut down without any operation for 5 minutes
Miscellaneous indicators
0 ℃-50 ℃; max 95% RH non-condensing; host size: 220x82x66mm, Weight 510g
HI93703-11
Turbidity Meter
Measurement range 0.00-50. 00FTU, 50-1000FTU, range automatic identification range conversion, resolution 0.01FTU (0.00-50. 00FTU), 1FNU (50-1000FTU), custom 890nm Infrared source, suitable for water quality monitoring, wastewater field and laboratory measurement use.
HANNA HI93703-11 Dual range turbidity Tester Picture

Introduction

HI93703-11 portable dual-range Turbidimeter complies with ISO7027 measurement standards, and automatically converts measurements between low turbidity range (0.0–50.00FTU) and high turbidity range (50–1000FTU). The built-in excellent optical system, combined with a special large cuvette and a light-shielded measurement tank, allows for a higher light source pass rate and effectively reduces the impact of light source fluctuations and stray light.

AMCO-AEPA-1 special turbidity calibration set is non-toxic and harmless, has stable performance and can be stored and reused for a long time. Used to regularly calibrate the internal curve to ensure accurate instrument measurement. It is widely used in water quality monitoring, wastewater field and laboratory measurement.

Characteristics

  • Automatic range conversion and built-in turbidity standard calibration point to ensure measurement accuracy;

  • Unique GLP management function can automatically store the last calibration date;

  • Comply with ISO7027 turbidity standard, FTU is formazine turbidity unit;

  • 199 sets of data storage and RS232 data interface facilitate data transmission, management and analysis;

  • Battery power display, timely reminder to replace the battery, automatic shutdown power saving mode.

Turbidity unit conversion

Turbidity unit conversionJTUFTU(NTU/FNU)ASBCEBCSiO2(mg/L)
JTU119//2.5
FTU(NTU/FNU)0.05310.05740.13
ASBC
17.51690.13
EBC/0.250.0141/
SiO2(mg/L)/7.5//1


FAQ
QWe do water quality monitoring and need to measure turbidity. Do you recommend any portable instruments?
A HANNA HI93703-11 portable turbidity meter is recommended, it conforms to ISO7027 standard, automatic range conversion, low range 0-50FTU and high range 50-1000FTU can be measured, high accuracy and GLP management, suitable for on-site water quality monitoring and wastewater testing.
QLaboratory measurement of water sample turbidity, which instrument to choose?
A Select the HI93703-11 turbidity instrument, which has a built-in Optical inspection system to reduce the influence of stray light, and uses a large Colorimetric dish for more accurate measurement. It also supports 199 groups of Data storage and RS232 interfaces, which is convenient for laboratory data management and analysis.
QNeed to measure different ranges of turbidity, can the instrument automatically switch the range?
A Yes, HI93703-11 automatically recognizes 0-50FTU and 50-1000FTU ranges and converts them, with resolutions of 0.01 and 1FTU respectively, making it easy to operate and suitable for variable water sample conditions, such as covering from clean water to turbid wastewater.
Knowledge
Standard