Measurement range | 1 ppm to 5% |
resolution | 0.1 ppm |
unit of result | %,ppm,mg/g,μg/g,mg,μg,mg/ml,μg/ml,ppt,mgBr/100g,gBr/100g,mgBr,gBr |
Sample category | Liquid or solid (externally dissolved or extracted) |
pre-titration condition | automatic |
Background drift correction | Automatic or user-selectable |
endpoint metric | Fixed mV continuous, relative drift stop or absolute drift stop |
Measurement | Dynamic with 3 speed settings |
result statistics | Mean, standard deviation |
Titration container type | Borosilicate Glass with Standard Cone Glass Joints |
operation volume | 100 - 200 ml |
Titration vessel diaphragm | silicone rubber |
Diaphragm cap thread | GL-18 |
reagent port | Standard taper 19 |
Electrode type/connection | HI76330 |
Glass connection | Standard taper 14/20 |
Polarization current | 1,2,5,? 10μA |
voltage range | 2 - 1100 mV |
voltage resolution | 0.1 mV |
Accuracy @25 ℃ | ±0.1% |
Generator electrode model | Diaphragm or no diaphragm |
Detection electrode type | automatic |
Electrical connection | 5-Pin connector with detachable cable |
Glass connection | Standard taper 29/12 |
Maximum current | 400 mA |
current control | Automatic or fixed (400mA) |
Type of mixing equipment | Magnetic, Electronic Regulation, Digital Stirrer |
Stirring speed | 200 - 2000 RPM |
Stirring resolution | 100 RPM |
External Stirrer | 4-Pin mini-DIN connection allows control of external mixing equipment |
Type of reagent processing system | A sealing system with integrated diaphragm air pump |
Type of drying agent | molecular sieve |
Bottle thread type | GL-45 |
Glass connection | Standard taper 19 (using adapter provided) |
Reagent/Waste Tube | PTFE |
show | 5.7 "Graphic Color Display with Backlight |
peripheral equipment | PC (USB Standard B); Flash Drive (USB Standard A); Analytical Balance (DB-9 socket); Printer (DB-25 socket); Keyboard (6-pin Mini-DIN) |
language | English |
Power Consumption | 100-240 VAC,50/60 Hz / 0.5 Amps |
Plate material | ABS/PC and stainless steel |
keyboard | Polyester brazing |
Operating conditions | 10 - 40 0C;80% RH |
Preserving the environment | -20 - 70 0C;95% RH |
Size/weight | 315 x 205 x 375 mm / 4.3kg |
Warranty days: 365 days
1. For product quality problems caused by non-human products of instruments and equipment, the manufacturer will provide free warranty services during the warranty period;
2. There is no warranty period for fragile and consumable parts, and if you find product quality problems after receiving the goods, please apply for return and exchange within 7 days, and you will not wait for the overdue ones;