Italy

HANNA HI98194 multiparameter Water Quality Analyzer (12 parameters)

SE
Acidity pH, pH, mV conversion, oxidation reduction ORP, conductivity EC, Electrical resistivity and other conventional important 12 water quality indicators rapid and accurate measurement, allowing users to store up to 45,000 continuous or on-demand log samples, graphical display allows the use of virtual keys to provide an intuitive user interface.
$2474.00/set
PromotionLoading...
Coupon
Model:

HANNA HI98194 Multiparameter DetectorSPEC

HANNA HI98194 Multiparameter DetectorDetails

HANNA HI98194 Multiparameter DetectorPacking list

SKU
NB045297
pH resolution
0.01pH
Measurement Accuracy of pH
±0.02pH
pH calibrated
Automatic one-point, two-point, or three-point, automatically recognizes five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
Acid alkalinity calibrated
±2000.0 mV
ORP resolution
0.1mV
ORP Accuracy
±1.0 mV
ORP calibrated
Automatic at a custom point (relative to mV)
mV range
±600.0 mV
mV resolution
0.1mV
mV Measurement Accuracy
±0.5mV
EC Series
0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC resolution
automatic range
EC Accuracy
+/- 1% or +/- 1 μS/cm of the reading, whichever is greater
EC calibrated
Automatic single point with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom points
TDS parameter
0 to 400,000 ppm (mg/L); (MAX Maximum depending on TDS coefficient)
TDS Resolution
manual
TDS Accuracy
+/- 1% of the reading or +/- 1 ppm (mg/L), whichever is greater
TDS calibrated
Based on conductivity or salinity calibrated
Salinity (PSU) range
0.00 to 70.00 PSU
Salinity (PSU) resolution
0.01 Power Supply
Salinity (PSU) Accuracy
+/- 2% reading or +/- 0.01 PSU, whichever is greater
Salinity (PSU) calibrated
Based on conductivity calibrating
Salinity (Seawater Sigma) range
0.0 to 50.0 Sigma t , σ₀, σ₁₅
Salinity (Seawater Sigma) resolution
0.1 σt, σ₀, σ₁₅
Salinity Accuracy
±1 σt, σ₀, σ₁₅
Salinity (seawater sigma) calibrated
Based on conductivity or salinity calibrated
Resistivity range
0 to 999999Ω • cm; 0 to 1000.0 kΩ • cm; 0 to 1.0000 MΩ • cm
Resistivity resolution
Depends on resistivity reading
Resistivity calibrated
Based on conductivity calibrating
Dissolved oxygen measurement type
Polarography
Dissolved oxygen range
0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
Dissolved oxygen resolution
0.1%; 0.01 ppm (mg/L)
Dissolved oxygen Accuracy
0.0 to 300.0% saturation
Dissolved oxygen calibrated
Automatically one or two points at 0 and 100% or 100%, or a custom point
Dissolved oxygen temperature compensation
Automatically from 0.0 to 50.0 ° C (32.0 to 122.0 ° F)
Air pressure compensation
Automatic from 450 to 850 mmHg
Salinity compensation
Automatically from 0 to 70 g/L
Temperature range
Temperature range
Temperature Resolution
0.01 K,0.01 °C,0.01 °F
Temperature Accuracy
±0.15 °C;±0.27 °F;±0.15  K
Temperature calibrated
Automatically at a custom point
temperature compensation
Automatic from -5 to 55 ° C (23 to 131 ° F)
recording memory
45,000 records (continuous logging or recording of all parameters on demand)
recording interval
One second to three hours
connect
USB to PC with HI9298194 Hanna software installed
Battery Type/Lifespan
1.5V AA battery (4)/about 360 hours of continuous use without backlight (50 hours of backlight)
environment
0 to 50 ° C (32 to 122 ° F); Relative Humidity 100% (IP67)
Dimension
185 * 93 * 35.2Mm (7.3 * 3.6 * 1.4 inches)
Weight
400 grams (14.2 ounces)
Atmospheric pressure range
450 to 850 mmHg; mercury levels 17.72 to 33.46; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric pressure resolution
0.1 mmHg; 0.01 mercury content; 0.1 mbar; 0.001 psi; 0.0001 atmospheres; 0.01 kPa
Measurement Accuracy of atmospheric pressure
+/- 3 mm Hg within +/- 15% of the calibrated point
Atmospheric pressure calibrated
Automatically at a custom point
HI98194
Multiparameter Detector
Acidity pH, pH, mV conversion, oxidation reduction ORP, conductivity EC, Electrical resistivity and other conventional important 12 water quality indicators rapid and accurate measurement, allowing users to store up to 45,000 continuous or on-demand log samples, graphical display allows the use of virtual keys to provide an intuitive user interface.
HANNA HI98194 multiparameter Water Quality Analyzer (12 parameters) Picture

Introduction

Portable high-precision professional multi-parameter analysis meter, in line with IP67 international waterproof standards, acidity pH, pH, mV conversion, redox ORP, conductivity EC, resistivity, total dissolved solids TDS, salinity, dissolved oxygen, saturated dissolved oxygen, Quickly and accurately measure 12 important water quality indicators such as seawater specific gravity, atmospheric pressure, temperature, etc., automatically identify the measuring range and unit conversion; new appearance design, on-screen calibration operation step prompts, GLP function, quick query of relevant data, acidity verification function, automatic Identification calibration and user-defined calibration, automatic end point locking function, USB data interface, large-capacity data storage, and good data management.

Features

  • Backlit Graphic LCD Display, HI98194 features a backlit graphic LCD with on-screen help function that can display up to 12 parameters simultaneously. The graphical display allows the use of virtual keys to provide an intuitive user interface.

  • Waterproof protection, the meter is enclosed in an IP67 waterproof housing and can withstand immersion in 1 meter of water for up to 30 minutes. The probe has an IP68 protection rating and can be continuously immersed in water.

  • Quick Connect Digital Probe, the HI7698194 probe features a quick connect DIN connector for a waterproof connection to the meter.

  • Color-Coded, Field-Replaceable Sensors Quickly and easily replace sensors using field-replaceable screw-type connectors that are color-coded for easy sensor port identification.

  • Automatic sensor recognition, the probe and meter automatically identify the connected sensor. Any unused ports on the Detector will not display the parameter or the parameter cannot be configured.

  • Automatic temperature compensation, integrated temperature sensor allows automatic temperature compensation of pH, conductivity and dissolved oxygen measurements.

  • Automatic barometric pressure compensation, the instrument has a built-in barometer, and the user can select a unit for dissolved oxygen pressure compensation.

  • Standard or Quick Calibration, Quick Calibration provides fast single-point calibration of pH, conductivity and dissolved oxygen. The standard pH calibration option allows you to select three points for calibration from five standard buffers and one custom buffer. Conductivity calibration is a single point calibration from a selection of six standards or a custom standard. Dissolved oxygen calibration can calibrate up to two standard points or a single custom point.

  • GLP Data, HI98194 includes GLP functionality, allowing users to view calibration data and expiry information at the touch of a button. Calibration data includes date, time, buffer/standard used for calibration, and slope characteristics.

  • For data logging, the HI98194 allows users to store up to 45,000 continuous or on-demand log samples with logging intervals from one second to three hours.

  • Intuitive keyboard, mounted rubber keyboard features dedicated power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that guide the user through configuration of each parameter, meter setup and data logging. The interface is intuitive for any user experience level.

  • Dedicated Help key, contextual help is always available via the dedicated "HELP" key. Clear on-screen tutorial messages and instructions quickly guide users through setup and calibration. The help information displayed is relevant to the setting/option being viewed.

  • PC connection, recorded data can be transferred to a Windows-compatible PC using the included HI920015 micro USB cable and HI9298194 software.

  • The battery life is long and the meter has a battery icon indicator light on the display to show remaining power. The meter uses four 1.5VAA batteries, which provide up to 360 hours of battery life.

  • Rugged Thermoformed Carrying Case The HI98194 meter, probe and all accessories are supplied in a rugged, durable carrying case designed to provide many years of use. The interior compartments of the suitcase are thermoformed to securely secure and protect all components.

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard