HANNA HI97738 Chlorine dioxide [chlorophenol red method] Portable photometer
SE
Measurement range of chlorine dioxide 0.00 to 2.00 mg/L (as ClO2), resolution 0.01 mg/L, accuracy @25 ℃: +/- 0.01 mg/L +/- 5% of reading, commonly used in drinking water treatment, swimming pool disinfection, industrial production and other fields.
1.5V AA battery (3), greater than 800 hours (without backlight)
Automatic shutdown
Automatic shutdown after 15 minutes without operation
Applicable environment
0 to 50℃;RH-max100% IP67
Size/Weight
142.5 x 102.5 x 50.5 mm,380g
HI97738
Chlorine dioxide [chlorophenol red method] Portable Photometer
Measurement range of chlorine dioxide 0.00 to 2.00 mg/L (as ClO2), resolution 0.01 mg/L, accuracy @25 ℃: +/- 0.01 mg/L +/- 5% of reading, commonly used in drinking water treatment, swimming pool disinfection, industrial production and other fields.
Introduction
HI97738 Chlorine Dioxide [Chlorophenol Red Method] Portable Photometer is an instrument used to measure the content of chlorine dioxide (ClO2) in water. Chlorine dioxide is a strong oxidant commonly used in water treatment and disinfection processes. It can effectively kill bacteria, viruses and other microorganisms in water, and can remove odor and color. It is often used in drinking water treatment, swimming pool disinfection, industrial production and other fields to ensure that water quality reaches safety standards and meets the requirements of relevant regulations.
HI97738 Chlorine Dioxide [Chlorophenol Red Method] Portable Photometer complies with IP67 waterproof standards, adopts innovative optical system design, has good accuracy, repeatability and time required to make measurements, CAL CheckTM function allows the use of NIST traceable standards Performance verification and calibration of the instrument, multiple measurement methods, built-in reaction timer to ensure consistent results between sample measurements and users, Good Laboratory Practice (GLP) display of the date and time of the last user calibration, battery status indicator light and automatic shutdown settings.
Features
LED high-quality light source system has good performance and high luminous efficiency;
High-quality optical filters, high measurement stability and less wavelength error ensure measurement precision and accuracy;
Unique reference Detector enables fast and stable readings between blank (zero) measurement and sample measurement;
Stable light source settings reduce errors and reading offsets caused by defects in glass cuvettes;
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.