HANNA HI708 Nitrite HR Tintometer

SE
Measurement range 0 to 150 ppm NO2, resolution 1 ppm, accuracy +/- 3 ppm +/- 5% of the reading, enabling measurement in a short time, suitable for applications requiring fast feedback.
$190.00/set
PromotionLoading...
Coupon
Model:

HANNA HI708 Nitrite HR TintometerSPEC

HANNA HI708 Nitrite HR TintometerDetails

HANNA HI708 Nitrite HR TintometerPacking list

SKU
NB045592
Measurement range
0 to 150 ppm NO2
resolution
1 ppm
Accuracy
+/- 3 ppm +/- 5% of the reading
Light source
LED @575nm
Automatic shutdown
No operation after ten minutes
Measuring method
Reference ferrous sulfate method
optional reagents
HI708-25
calibration group
HI708-11
HI708
Nitrite HR Tintometer
Measurement range 0 to 150 ppm NO2, resolution 1 ppm, accuracy +/- 3 ppm +/- 5% of the reading, enabling measurement in a short time, suitable for applications requiring fast feedback.
HANNA HI708 Nitrite HR Tintometer Picture

Introduction

Nitrification refers to the process in which ammonia (ammonium ions) is converted into nitrite and then into nitrate under biological oxidation. During one stage of the nitrification process, nitrifying bacteria convert ammonium ions into nitrite. Nitrite, like ammonia, is a toxic and harmful substance, so the content of the above two substances in the water must be controlled at an undetectable concentration level. A mature biofilter should also keep nitrites at low levels.

HI708 Nitrite HR Colorimeter is an instrument used to measure high-concentration nitrite in water samples. It is usually used in drinking water treatment, wastewater treatment, environmental monitoring and other fields, especially when rapid detection of high-concentration nitrite is required. situation.

Features

  • It can measure nitrite in a higher concentration range and has higher sensitivity.

  • With high precision and accuracy, it can provide reliable measurement results.

  • It can complete the measurement in a short time and is suitable for applications requiring fast feedback.

  • It can be widely used in drinking water treatment, wastewater treatment, environmental monitoring and other fields.

  • No complicated operating steps are required, and it is suitable for laboratory and field testing.

FAQ
QI want to measure the nitrite concentration in the water, probably tens to more than 100 ppm, what instrument do you recommend?
A HANNA HI708 nitrite photometer can measure high concentration of 0-150ppm nitrite, resolution 1ppm, high accuracy, suitable for drinking water treatment, wastewater detection and other scenarios that require rapid height concentration data.
QTo measure nitrite on site, is there an instrument with simple operation points?
A The HI708 photometer is very suitable. It is lightweight in design and uncomplicated in operation. It can quickly produce results with the matching reagent HI708-25. It automatically shuts down and saves electricity. It is especially suitable for rapid detection of high-concentration nitrite in the field or on-site in sewage treatment plants.