HANNA HI771 total chlorine UHR Tintometer

SE
Measurement range 0 to 500 ppm, resolution 1 ppm, accuracy +/- 3 ppm +/- 5% of the reading, has important applications in water treatment, environment monitoring, industrial production and other fields.
$192.00/set
PromotionLoading...
Coupon
Model:

HANNA HI771 Total chlorine UHR TintometerSPEC

HANNA HI771 Total chlorine UHR TintometerDetails

HANNA HI771 Total chlorine UHR TintometerPacking list

SKU
NB045621
Measurement range
0 to 500 ppm
resolution
1 ppm
Accuracy
+/- 3 ppm +/- 5% of the reading
Light source
LED @525nm
Automatic shutdown
No operation after ten minutes
Measuring method
Refer to USEPA method 330.5, DPD method Refer to water and wastewater standard detection method 20th edition, 4500-CI method
optional reagents
HI771-25
calibration group
HI771-11
HI771
Total chlorine UHR Tintometer
Measurement range 0 to 500 ppm, resolution 1 ppm, accuracy +/- 3 ppm +/- 5% of the reading, has important applications in water treatment, environment monitoring, industrial production and other fields.
HANNA HI771 total chlorine UHR Tintometer Picture

Introduction

Chlorine is a commonly used water disinfectant, but excessive chlorine in water can form toxic and harmful substances. Therefore, it is crucial to monitor the chlorine content in swimming pool and hot spring water, water for cleaning fruits and vegetables, and drinking water. HI771 Total Chlorine UHR Colorimeter is an instrument used to measure the total chlorine concentration in water. The concentration of total chlorine in the water sample is determined by comparing the intensity of the color produced by the reagent. In many cases, especially when processing sewage, wastewater or other water samples containing chlorine compounds, it is necessary to measure the total chlorine concentration in the water to ensure that the water quality is up to standard or that appropriate treatment is carried out.

In addition, the HI771 total chlorine UHR Colorimeter has important applications in water treatment, environmental monitoring, industrial production and other fields. It can help users monitor and control the total chlorine concentration in water to ensure that water quality meets relevant standards and requirements.

Features

Compared with traditional tungsten lamps and other light sources, LED light sources have better performance and higher luminous efficiency. They can use less energy to provide a stable light source. LEDs can ignore the heat they generate because higher heat will affect electronic products. stability.

HANNA's carefully designed CAL CheckTM function allows performance verification and calibration of the instrument using NIST traceable standards; CAL CheckTM NIST curve calibration set is used to simulate specific absorbance values ​​at each wavelength to verify the accuracy of subsequent readings.

FAQ
QI want to measure the total chlorine in swimming pool water, which instrument is suitable?
A Recommended HI771 total chlorine Tintometer, it is specially designed for swimming pool water quality, using DPD method measurement 0-500ppm total chlorine, simple operation, can quickly determine whether the disinfectant is excessive, to avoid chlorine exceeding the standard harm to health.
QCan HI771 measure chlorine in drinking water? What are the advantages of choosing it?
A Can measure the total chlorine in drinking water. Recommended reasons are: 1. The range covers 0-500ppm, including the typical detection range of drinking water 2. The matching special reagent (HI771-25), the operation is directly Colorimetric, no need for complicated preparation 3. Automatic calibration verification function of the instrument, which can ensure the measurement Reliability for a long time.
Standard