HANNA HI96821 sodium chloride refractive analyzer (fresh water sample)

SE
(G/100g) Measurement range 0 to 28, (g/100mL) Measurement range 0 to 34, specific gravity (S.G.) Measurement range 1.000 to 1.216, can display 4 different reference units, stainless steel sample chamber, easy to clean and anti-corrosion.
$486.00/set
PromotionLoading...
Coupon
Model:

HANNA HI96821 Sodium chloride refractive analyzerSPEC

HANNA HI96821 Sodium chloride refractive analyzerDetails

HANNA HI96821 Sodium chloride refractive analyzerPacking list

SKU
NB045673
Measurement range - (g/100g)
0 to 28
Resolution - (g/100g)
0.1
Accuracy(@25 C/77° F)-(g/100g)
±0.2
Measurement range - (g/100mL)
0 to 34
Resolution - (g/100mL)
0.1
Accuracy(@25 C/77° F)-(g/100mL)
±0.2
Measurement range - specific gravity (S.G.)
1.000 to 1.216
Resolution - specific gravity (S.G.)
0.001
Accuracy (@25 C/77 ° F) - specific gravity (S.G.)
±0.002
Measurement range - ° Baumé
0 to 26
Resolution - ° Baumé
0.1
Accuracy @25 C/77 ° F - ° Baumé
±0.2
Measurement range
0 to 80 ℃(32 to 176 ℉)
temperature resolution
0.1℃(0.1 ℉)
Temperature Accuracy @25 C/77 ° F
±0.3℃(±0.5 ℉)
Temperature compensation
10 ℃ to 40 ℃ automatic temperature compensation
Measurement time
Approximately 1.5 seconds
Minimum sample Volume
100 μL (covering all prisms)
Light source
Yellow LED
Sample room
Stainless Steel Sample Chamber, Hard Glass Prism
Automatic shutdown
After 3 minutes of use
Protection level
IP65
Power/Battery life
9V/about 5000 sets of readings
basic configuration
Host, battery and instruction manual
HI96821
Sodium chloride refractive analyzer
(G/100g) Measurement range 0 to 28, (g/100mL) Measurement range 0 to 34, specific gravity (S.G.) Measurement range 1.000 to 1.216, can display 4 different reference units, stainless steel sample chamber, easy to clean and anti-corrosion.
HANNA HI96821 sodium chloride refractive analyzer (fresh water sample) Picture

Introduction

HI96821 refractometer measures the refractive index of a liquid solution sample and converts it into the sodium chloride content of the sample. It is specially used for the food industry and is not suitable for seawater salinity measurement.

The refractive index measurement is very simple and fast. The user only needs to calibrate the refractometer with distilled or deionized water and then add two drops of the sample to be measured into the sample chamber. The sodium chloride measurement value of the sample to be measured can be obtained within a few seconds. . The instrument automatically performs temperature compensation, and the measurement results are accurate and reliable. Samples are measured after simple user calibration using deionized or distilled water. The instrument measures the refractive index of the solution within seconds, performs the necessary calculations, and displays the results in selected units. Digital refractometers eliminate the uncertainties associated with mechanical refractometers, allowing portable measurements where needed.

The instrument adopts internationally recognized reference unit conversion and temperature compensation methods and can display NaCI concentration in 4 different reference units: g/100g, g/100 mL, specific gravity and °Baumé (degrees of Baume). The second line of the LCD screen can simultaneously display the measured temperature, low battery prompt icon and other help information.

Characteristics

  • Two-line LCD display with temperature reading below the measured value.

  • ATC, automatic temperature compensation.

  • BEPS, low battery reminder, ensures accurate and effective readings.

  • IP65 waterproof, suitable for laboratory and field measurements.

  • Fast and accurate measurement, measurement results are quickly displayed in 1.5 seconds.

  • One-point calibration, use distilled or deionized water.

  • For micro-volume samples, only 2 drops of sample are needed.

  • Automatically shuts down if not used for three minutes.

  • Stainless steel sample chamber, easy to clean and anti-corrosion.

  • Easy to operate, just drop the sample and press the button to read, simple and fast.

  • ABS heat shrink plastic carrying case.

FAQ
QHow do I switch between Measurement units and Temperature units?
A Concentration Unit switch: Press the RANGE key to cycle to switch G-G (g/100g), G-L (g/100mL), S. G (specific gravity), BAU (weight). Temperature Unit switch: Press and hold the ON/OFF key for 8 seconds to enter the setting mode. Keep pressing the ON/OFF key, and then press the ZERO key to switch ° C/° F.
QHow do you know if the prism should be replaced?
A It can be seen with the naked eye that there are scratches or fog, and the calibrating fails all the time. The same sample has been tested several times, and the results are much different. Generally, it takes two years or about 5,000 times to check.
QCan you test other liquids? Such as sugar water?
A This machine is dedicated to measuring saline water concentration. Measurement of other liquids may: the number is inaccurate, the prism is broken, and then the measurement of saline water is also inaccurate. To measure other liquids, you have to buy Miscellaneous models.