HANNA HI93102 Portable multiparameter Tester (EPA standard)

SE
Multiparameter measurement system, turbidity, chlorine, acidity pH, bromine, iron, iodine and cyanuric acid (CYAC) including a total of 7 water quality parameters, portable design, laboratory grade Measurement accuracy, widely used in water quality analysis, drinking water quality monitoring and other fields.
$1984.00/set
PromotionLoading...
Coupon
Model:

HANNA HI93102 Portable multiparameter meter (EPA standard)SPEC

HANNA HI93102 Portable multiparameter meter (EPA standard)Details

HANNA HI93102 Portable multiparameter meter (EPA standard)Packing list

SKU
NB045678
Measurement range - turbidity
0.00 to 9.99NTU、10.0 to 50.0NTU
Resolution - turbidity
0.01NTU (≤9.99NTU)、0.1NTU(≤50.0 NTU)
Measurement Accuracy - turbidity
+/- 5%/0.5NTU@25 ℃/77 ° F whichever is greater
Measuring method - turbidity
Turbidity (90 ℃) or scattering turbidity (90 ℃ & 180 ℃), conforming to USEPA Method 180.1 and Standard 2130B
Calibrated mode - turbidity
Two-point calibrated, 0.00--50.0FTU optional, 0.00 and 20.0FTU standard points recommended
Measurement range -PH
5.9 to 8.5pH
Resolution-PH
0.1pH
Measurement Accuracy @25 ℃ -PH
±0.1pH
Measurement range - residual chlorine
0.00 to 2.50mg/L Cl2
Resolution - residual chlorine
0.01mg/L
Measurement Accuracy @25 ℃ - residual chlorine
+/- 3% of reading +/- 0.03mg/L
Measurement range - total chlorine
0.00 to 3.50mg/L Cl2
Resolution - total chlorine
0.01mg/L
Measurement Accuracy @25 ℃ - total chlorine
+/- 3% of reading +/- 0.03mg/L
Measurement range - Cyanuric acid
0 to 80mg/L Cys
Resolution - Cyanuric acid
1mg/L(ppm)
Measurement Accuracy @25 ℃ - cyanuric acid
+/- 15% of reading +/- 1mg/L
Measurement range - Iodine
0.0 to 12.5mg/L l2
Resolution - Iodine
0.1mg/L(ppm)
Measurement Accuracy @25 ℃ - Iodine
+/- 5% of reading +/- 0.1mg/L
Measurement range - Bromine
0.00 to 8.00mg/L Br2
Resolution - Bromine
0.01mg/L(ppm)
Measurement Accuracy @25 ℃ - Bromine
+/- 3% of reading +/- 0.08mg/L
Measurement range - Iron
0.00 to1.00mg/L Fe
Resolution - Iron
0.01mg/L(ppm)
Measurement Accuracy @25 ℃ - Iron
+/- 3% of reading 0.02mg/L
Optical inspection system
Custom Dedicated Receiver & Light source System
Measuring method -pH
Colorimetry of phenol red, acidity reagent reacts with acidic substances in red; iron-Fe: using TPTZ method, iron reacts with reagent in light blue
Measuring method - total nitrogen
Refer to USEPA method 330.5 and Standard Method 4500-Cl G. with DPD reagent, the reaction is light pink;
Measuring method - Cyanuric acid
Refer to Nephilometry. Cyanuric acid reacts with reagents to form white suspended solids; bromine, iodine: in line with EPA, DPD methods
Power mode
4X1.5VAA battery; automatic shutdown time setting: 10, 20, 30, 40, 50, 60 minutes
Miscellaneous indicators
0 to 50 ℃ (32 to 122 ° F); RH max 95%, no condensation, host size: 220x82x66mm, Weight: 510g
HI93102
Portable multiparameter meter (EPA standard)
Multiparameter measurement system, turbidity, chlorine, acidity pH, bromine, iron, iodine and cyanuric acid (CYAC) including a total of 7 water quality parameters, portable design, laboratory grade Measurement accuracy, widely used in water quality analysis, drinking water quality monitoring and other fields.
HANNA HI93102 Portable multiparameter Tester (EPA standard) Picture

Introduction

The multi-parameter measurement system can quickly measure a total of 7 water quality parameters including turbidity, chlorine, acidity pH, bromine, iron, iodine and cyanuric acid (CYAC). Portable design, laboratory-level measurement accuracy, widely used in water quality analysis, drinking water quality monitoring and other fields.

Complying with USEPA180.1 standard and Standard Method 2130B standard method, the microprocessor calculates the turbidity value through the light intensity reaching the photoDetector; it effectively corrects color interference, and has chromaticity compensation and automatic light source compensation functions to avoid light source Interference caused by fluctuations eliminates the need for frequent calibration.

Characteristics

  • Excellent optical system design and humanized operation ensure good calibration of the instrument;

  • Manual calibration, built-in standard calibration points: 0, 20NTU, in line with USEPA method;

  • Built-in standard curve calibration before leaving the factory, with CAL CHECK performance verification function;

  • GLP function, update and check calibration data, date, standards and other information at any time;

  • The reaction time between reagents and samples is consistent to ensure measurement accuracy;

  • High-precision measurement results, light source dust-proof measurement system, automatic shutdown power-saving mode.

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.