China

HUXI HLS-1312F high-precision chiller 13L/1200W

SE
Water tank volume 13L, Temperature range 5-35 ℃, Stability +/- 0.1 ℃, refrigeration power 1200W, pump Flow rate 4L/min@1.5bar
$1607.00/set
PromotionLoading...
Coupon
Model:
Certificate

HuXi HLS-1312F High-precision chillerSPEC

HuXi HLS-1312F High-precision chillerDetails

HuXi HLS-1312F High-precision chillerPacking list

SKU
NB046601
Model
small
Power Supply
220V/50Hz
cooling Capacity
1200W
Refrigerant
R22
freezing Capacity
1200w
Compressor type
Rotor compressor
Input Power
0.45Kw
Refrigerant type
R22
Condenser type
finned
air Volume
560m²/h
Type of evaporator
Stainless steel coil
Water tank Volume
13L
Temperature control type
start stop
Humidity range
5-35℃
Temperature Accuracy
0.1℃
Temperature display
liquid crystal
Pump type
diaphragm pump
Power
100W
rated pressure
1.5bar
Rated head
15m
Flow rate
4L/minr
maximum pressure
4bar
Flow rate
5L/min
Water inlet and outlet pipe diameter
DN15
Rated Power
500W
Shell material
Q235 spray
Instrument size
400x550x670mm
Packaging Dimensions
470x620x850mm
Net Weight of instrument
46kg
Instrument Gross Weight
55kg
HLS-1312F
High-precision chiller
Water tank volume 13L, Temperature range 5-35 ℃, Stability +/- 0.1 ℃, refrigeration power 1200W, pump Flow rate 4L/min@1.5bar
HUXI HLS-1312F high-precision chiller 13L/1200W Picture

Introduction

The high-precision chiller is a high-end model designed for the needs of high-quality analytical instruments, which is mainly used in the fields of atomic absorption instrument, spectrometer, mass spectrometer, scanning electron microscope, lens electron microscope, Soxhlet extractor, diffusion pump, molecular pump, Kjeldahl nitrogen meter, ion thinning instrument, Fourier transform mass spectrometry (FIS), magnetron sputtering instrument, small vacuum coater and other analytical instruments.

Features

  • High-performance circulating water pump, the pressure of the Circulating Chiller is steplessly adjustable;

  • Detachable dust net cover, maintenance is very convenient, user operation is easier, installation and debugging are more convenient and fast;

  • The refrigeration function and circulation function can be controlled independently or simultaneously;

  • The combination of proportional refrigeration technology, hot gas bypass technology and PID control technology has high temperature control accuracy;

  • Temperature protection, water pressure protection, overheating and overcurrent protection and other multiple safety protections to ensure the safety of experiments;

  • A variety of operation modes are available, and the unexpected power failure can be automatically restored, which can ensure the continuous supply of cooling circulating water;

  • The imported compressor and ultra-quiet fan are used to make the noise of the whole machine very low, especially suitable for laboratory environment;

  • Alarm reminder function, light and sound reminder at the same time when alarming, the code is directly displayed, and the error point can be directly determined;

  • Multiple purification water quality design: a filtration device is configured in the primary Water Tank to purify water quality; The careful selection of the material of the double waterway ensures the cleanliness of the water in the pipeline; Triple standard water filter for purification to meet the water quality requirements of external analytical instruments.

FAQ
QThe atomic absorption instrument in our laboratory needs to be equipped with a chiller. Is there any recommendation?
A HUXI HLS-1312F high-precision chiller is recommended. It is designed for analytical instruments such as atomic absorption meters, using proportional refrigeration and PID temperature control technology, with a temperature accuracy of 0.1 ° C to ensure stable operation of the instrument. Multiple water purification designs can also meet the strict requirements of atomic absorption meters for water quality.
QSEM Laboratory Environmental requirements Quiet, chiller noise?
A HUXI chiller is suitable for laboratories. It uses imported compressor and ultra-quiet fan, and the noise is very low during operation, which will not interfere with the precise operation of sem. At the same time, it has multiple Safety protection to ensure the safety of valuable instruments.
QThe atomic absorption instrument in our laboratory needs a chiller. Do you have any recommendations?
A The HLS-1312F high-precision chiller is specially designed for analytical instruments such as atomic absorption meters, with a temperature control accuracy of 0.1 ° C, which can ensure the stable operation of the instrument and avoid temperature fluctuations affecting the detection results.
QLight spectrum instrument laboratory has any special requirements for chillers?
A Light spectrum instrument needs continuous and stable chill down, HUXI this chiller uses proportional refrigeration and PID control technology, precise temperature control, and multiple protection and water purification design, can effectively protect the precision Optical inspection components.