YUEPING DC-0510 Thermostatic Bath volume 10 liters Temperature range -5 ℃~ 100 ℃

SE
Temperature range -5~ 100 ℃, Temperature Fluctuation +/- 0.5 ℃, working tank volume 10L, slot opening size 180 * 140mm, working bath depth 200mm, circulation mode internal/external circulation, total Power 1350W.
$969.00/set
PromotionLoading...
Coupon
Model:
Certificate

YuePing DC-0510 Thermostatic BathSPEC

YuePing DC-0510 Thermostatic BathDetails

YuePing DC-0510 Thermostatic BathPacking list

SKU
NB004762
Temperature range
-5~100℃
Temperature Fluctuation
±0.5℃
Tank Volume
10L
Tank opening Dimensions
180*140mm
Tank Depth
200mm
Temperature control mode
Continuous PID automatic control
Circular mode
Internal/external circulation
Total Power
1350W
Power
220V 50Hz
Tank Size
250*200*200mm
refrigeration method
Air-cooled hermetic compressor refrigeration
DC-0510
Thermostatic Bath
Temperature range -5~ 100 ℃, Temperature Fluctuation +/- 0.5 ℃, working tank volume 10L, slot opening size 180 * 140mm, working bath depth 200mm, circulation mode internal/external circulation, total Power 1350W.
YUEPING DC-0510 Thermostatic Bath volume 10 liters Temperature range -5 ℃~ 100 ℃ Picture

Introduction

Yueping constant temperature bath DC-0510 is a low temperature constant temperature bath with a temperature control range of -5°C~100°C and a bath depth of 200mm. The constant temperature bath DC-0510 uses an LED digital display and has a volume of 10 liters.

Specifications

modelDC-0510DC-1010DC-2010DC-3010DC-4010
Temperature range (°C)-5~100-10~100-20~100-30~100-40~45
Temperature fluctuation (°C)±0.5±0.5±0.5±0.1±0.1
Working tank volume (mm³)250x200x200250x200x200250x200x200250x200x200250x200x200
Working tank opening size (mm²)180x140180x140180x140180x140180x140
Groove depth (mm)200200200200200
Total power (kw)1.351.41.51.552.2

Features

1. The temperature is set by LED digital, digital display, continuous PID automatic control.

2. The circulation pump of Yueping 10-liter constant temperature tank DC-0510 can lead the constant temperature liquid in the tank to the outside to establish a second constant temperature field; it can also be used as a cold source (heat source) to lead out the refrigerated (heated) liquid in the tank , to reduce (raise) the temperature of the external experimental container of the tank, and expand the scope of use.

3. The Low Temperature Circulating Bath adopts air-cooled fully enclosed compressor for refrigeration, with fast cooling speed, low noise and convenient operation. The power supply is 220V, 50Hz.