TASI-675 Film Thickness Gauge Taiwan, CHINATesans manufactures a hand-held magnetic permeability Film Thickness Gauge with a gun-like structure and a monochrome LCD display that displays the measured thickness data in real time during the measurement process.TASI-675 Film Thickness Gauge is a Thickness Gauge with built-in thickness sensor, the measurement range is 0~1000 microns, suitable for measuring the film thickness of coatings on ferrous metal substrates, with high measurement sensitivity and simple operation.
The TASI-675 Thickness Gauge is specifically designed to be operated with one hand. The iron-based Film Thickness Gauge not only has a display backlight reading function for reading the display reading value in the dark, but also has an automatic reading lock function and an automatic shutdown function to prolong the battery life.
1. It can measure magnetic permeability.
2. Two-point correction provides better measurement accuracy.
3. Users can choose μm/mils.
4. Backlight display, automatic shutdown function.
5. Simple, lightweight, one-handed operation.




1. "☀" button: used to turn on the backlight function, turning on the backlight can help users still check the thickness reading displayed by the LCD display in the environment with insufficient lighting.
2. "mils/μm" button: when the machine is turned on, it can be used to switch the thickness display unit to mils or μm. (1μm=milsx25.4)
3. "CAL" key:
1) When the machine is on, press and hold "CAL" and "▼" for four seconds at the same time to make a little correction.
2) When the machine is turned on, press and hold "CAL" for four seconds to perform two-point correction.
3) When performing one-point correction and two-point correction, press "CAL" to confirm to enter the next step after the reading value is displayed, and press and hold "CAL" for four seconds to leave the correction mode.
1. Before using the Film Thickness Gauge, please read the operation safety instructions and user manual
2. Do not place the Film Thickness Gauge near any device that generates a strong magnetic field or electrostatic field, as this may cause the Film Thickness Gauge to malfunction.
3. Do not use the Film Thickness Gauge when exposed to corrosive or flammable gases. This could disrupt the aftermath or cause an explosion.
4. Do not use the Film Thickness Gauge in an environment that is directly exposed to sunlight or condensation, as this may cause the Film Thickness Gauge to deform or the insulating cup to be damaged, or cause the Film Thickness Gauge characteristics to exceed the specifications.
5. One point correction: This action needs to be performed every time you take a measurement
6. Two-point calibration: It is recommended to perform this action at common test points to increase the accuracy of measurement.
Power on and off
1. Make sure that the front end of the Film Thickness Gauge sensor is away from any substrate or magnetic field
2. Press down the trigger until the screen is displayed, then release the trigger, and wait for the screen to display "um" or "mils" and HOLD before the measurement.
3. Automatic Power Off (APO): If there is no operation of the Film Thickness Gauge for 15 seconds, the power of the Film Thickness Gauge will be automatically turned off to prolong the battery life.
correction
1. Before performing the correction mode, select the unit first, and you cannot switch the unit when entering the correction mode.
2. When entering the correction mode, the automatic power off APO function will not be enabled.