China

FANGZHOU FZR-362 Portable ORP/pH Meter PH Level 0.01

SE
Level 0.01, pH Measurement range (-5.00~20.00) pH, mV/RelmV Measurement range (- 2000.0~2000.0) mV, ORP Measurement range (- 2000.0~2000.0) mV, Temperature Measurement range (-20.0~135.0) ℃, Storage quantity 5000 sets, GLP standard meets GLP standard.
$557.00/set
PromotionLoading...
Coupon
Model:
Certificate

FZchina FZR-362 Portable ORP/pH MeterSPEC

FZchina FZR-362 Portable ORP/pH MeterDetails

FZchina FZR-362 Portable ORP/pH MeterPacking list

SKU
NB047884
Instrument level
0.01 level
PH range
(-5.00~20.00)pH
pH resolution
0.01pH/0.1pH (adjustable)
pH electron unit intrinsic error
±0.01pH
Repeatability of pH electron unit
0.01pH
mV range
(-2000.0~2000.0)mV
mV resolution
0.1mV/1mV (adjustable)
mV/RelmV electronic unit intrinsic error
±0.1%FS
ORP Measurement range
(-2000.0~2000.0)mV
ORP resolution
0.1mV/1 mV (adjustable)
ORP electronic unit intrinsic error
±0.1%FS
ORP Electronic Unit Repeatability
1mV
ORP instrument matching error (ORP)
±15mV
Measurement range
(-20.0~135.0)℃/(-4.0~275.0)℉/(253.15~408.15)K
Temperature Resolution
0.1℃
Temperature electronic unit intrinsic error
±0.2℃
Temperature compensation range
(-20.0~135.0) ℃ (automatic/manual)
Input Impedance
≥1×1012Ω
Data storage
Storage quantity 5000 sets
GLP standard
GLP compliant
input/output
Sensors interface: electrode interface, temperature interface; Communication interface: USB Type-C
Power Supply
4 14500 3.7V rechargeable lithium batteries
FZR-362
Portable ORP/pH Meter
Level 0.01, pH Measurement range (-5.00~20.00) pH, mV/RelmV Measurement range (- 2000.0~2000.0) mV, ORP Measurement range (- 2000.0~2000.0) mV, Temperature Measurement range (-20.0~135.0) ℃, Storage quantity 5000 sets, GLP standard meets GLP standard.
FANGZHOU FZR-362 Portable ORP/pH Meter PH Level 0.01 Picture

Features

  • Large-screen LCD display, support backlight adjustment, table display, menu navigation operation

  • Support Chinese and English language interfaces

  • 3 temperature units available: Celsius (°C), Fahrenheit (°F), thermodynamic temperature (K)

  • It has functions such as self-diagnosis at power-on, automatic shutdown at a timed time, power-off protection and factory reset recovery

  • IP65 protection level is supported

Smart detection

  • Intelligent operating system with functions such as method setting, sensor management, calibration management, sample management, and user management

  • Allow users to set user ID, sample ID, support user hierarchical authority management, support password management

  • Supports measurement of pH, mV, RelmV, ORP, and T values

  • There are two ways to measure ORP: ORP relative to the reference electrode potential difference, and ORP relative to the hydrogen standard electrode potential difference

  • Built-in reference electrodes with 6 different structural configurations, Ag-AgCl electrode [saturated KCl], Ag-AgCl electrode [3mol/L KCl solution],

  • Ag-AgCl electrode [1mol/L KCl solution], calomel electrode [saturated KCl solution], calomel electrode [1mol/L KCl solution], calomel electrode [0.1mol/L KCl solution]

  • It can automatically identify 28 pH standards in 6 groups of GB, Merck, DIN19267, NIST, European, and United States, and the calibration points of the standard solution range from the minimum to 1.09 pH to the maximum 12.75 pH calibration, and the maximum 5 calibration points

  • It has electrode condition display, measurement limit, alarm function, and endpoint processing mode

  • ATC automatic recognition, automatic/manual temperature compensation

  • Five measurement modes: Manual Reading, Automatic Quick Reading, Automatic Medium Reading, Automatic Slow Reading, Timed Reading

  • ORP calibration is supported

  • Support 2 pH calibration fitting methods to meet the pH and ion concentration measurement of different samples

  • Dual clock and date display shows the current time and provides a time reference for digital recording functions

  • It has a timer storage function, and the timer storage time is: (5-3600) seconds

Data management and data traceability

  • Current and historical calibration data can be consulted, including calibration personnel, calibration temperature, calibration point pH and mV, slope, equipotential offset, calibration date and time

  • Support measurement value storage: Users and samples can be created dynamically, and no less than 5000 sets of data can be stored

  • GLP compliant, data traceability and statistical analysis are realized

  • With USB interface, the instrument can send the stored data to the computer acquisition software, and can export Excel files, notepad files, etc., which is convenient for users to archive and consult, statistical, analyze, compare and other operations of measurement data

power management

  • Powered by large-capacity lithium battery, it can be charged by mobile power bank and PC

  • It has the function of battery level display reminder and charging status reminder

  • Support backlight adjustment


FAQ
QI want to measure the pH value and Oxidation-reduction potential of swimming pool water. I need Portable. Do you have any recommendations?
A FZR-362 Portable ORP/pH Meter for on-site water quality testing, such as swimming pools. Because it supports the measurement of pH and ORP (Oxidation-reduction potential) two key indicators, and is a portable design, IP65 Protection Rating, take it out with no fear of splashing. Large screen display, simple operation, and automatic temperature compensation to ensure accurate measurement at different water temperatures.
QOur laboratory often needs to measure the pH of various solutions, and sometimes the sample Ion concentration varies greatly, which requires high accuracy and calibrating. Which one is suitable?
A The FZR-362 is ideal for precision measurement in the laboratory. It has high accuracy (0.01 level), supports up to 5 point calibrating, and can automatically identify 6 groups of 28 standard liquids. The calibrating range is wide (1.09 to 12.75pH), which can handle samples of various Ion concentrations. The instrument has a variety of built-in reference Electrode options, and there are two pH calibrating fitting methods, which can optimize the measurement results for different samples and ensure reliable data. It also complies with GLP standards, and the data can be traced, which is convenient for laboratory management.
Knowledge