China

Huicheng DSC-600S Differential Scanning Calorimeter FTC and STC Dual Mode 600 ℃

SE
Using imported alloy material Sensors, with 12-order program temperature control, multi-point temperature correction function, greatly improving sensitivity and resolution. With FTC and STC two experimental modes and multi-point temperature correction function, the experimental freedom is high, easy to operate
$5481.00/set
PromotionLoading...
Coupon
Model:
Certificate

HuiCheng DSC-600S Differential Scanning CalorimeterSPEC

HuiCheng DSC-600S Differential Scanning CalorimeterDetails

HuiCheng DSC-600S Differential Scanning CalorimeterPacking list

SKU
NB048375
DSC range
0~±2000mW
temperature range
Room temperature~ 600 ℃
Timer frequency
16.6Hz
Heating rate
0.1~100℃/min
Temperature Accuracy
0.001℃
Temperature Resolution
0.01℃
Temperature Fluctuation
±0.01℃
Temperature, repeability
±0.01℃
DSC noise
0.001mW
DSC resolution
0.01μW
DSC Accuracy
0.001mW
DSC sensitivity
0.001mW
experimental mode
FTC, STC arbitrary settings
programmed temperature control
Flexible setting of 12-step temperature control in all stages
Temperature control method
Heating, thermostatic, cooling
scan type
Heating, cooling, isothermal scanning
atmosphere control
The atmosphere of the two channels can be set freely, and the instrument can be automatically switched
display mode
24Bit color 7-inch LCD touch screen display
Data Interface
Standard USB port
sampling rate
1~ 10Hz programmable setting
Instrument calibrated
The lower computer and the upper computer have multi-point temperature correction function at the same time
parameter standard
Equipped with standard materials, users can adjust the temperature and enthalpy by themselves
instrument size
490*390*215mm
DSC-600S
Differential Scanning Calorimeter
Using imported alloy material Sensors, with 12-order program temperature control, multi-point temperature correction function, greatly improving sensitivity and resolution. With FTC and STC two experimental modes and multi-point temperature correction function, the experimental freedom is high, easy to operate
Huicheng DSC-600S Differential Scanning Calorimeter FTC and STC Dual Mode 600 ℃ Picture

As a classical thermal analysis method that can control the thermal effect at program temperature, differential scanning calorimetry (DSC) has been widely used in various occasions such as research and development, process optimization, quality control and failure analysis in various fields of materials and chemistry. Using the DSC method, we are able to study the phase transition of inorganic materials, the melting and crystallization process of polymer materials, the polymorphism phenomenon of drugs, and the solid/liquid phase ratio of foods such as oils and fats.

Instrument Usage

Measure the physical and chemical changes related to heat, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transition reaction heat, thermal stability of the product, curing/cross-linking, oxidation induction period, etc.

Features

  • The integrated design of the whole machine reduces signal loss and interference, greatly improves signal sensitivity and resolution, and can obtain a more stable baseline.

  • Equipped with imported high-frequency core control processor, the operation and processing speed is faster, and the control is more efficient.

  • The imported high-sensitivity sensor is adopted, which effectively improves the sensitivity and accuracy of DSC signal.

  • The independent atmosphere control can be intelligently set by software, and the instrument can automatically switch the gas circuit system, which makes the experimental efficiency higher.

  • The lower computer and the upper computer of the equipment system have multi-point temperature correction function at the same time, which meets the needs of different experimental occasions and improves the accuracy of temperature testing.

  • With two experimental modes of FTC and STC, the temperature control is more friendly and flexible, which can meet the needs of different experiments in different application scenarios, the temperature control of the experimental process is more accurate, and the analysis of sensor signals is more efficient.

  • The full temperature control system adopts the optimized dynamic PID algorithm, which greatly avoids the shortcomings of the traditional PID algorithm and improves the robustness of dual-mode temperature control.

  • The 12-step program temperature control setting makes the experimental methods more diverse.

  • The sampling frequency of the sensor signal can be set to 1~10Hz, the experimental method is more flexible, and the data is more controllable.

  • Dual temperature sensors are independent of each other to measure the furnace temperature and sample temperature separately at the same time.

  • The equipment system can do experiments on heating, cooling and isothermal related materials.

  • The instrument adopts USB two-way communication, supports self-recovery connection, intelligent software design, has the function of deducting the baseline, automatically plots the experimental process, and intelligently realizes the processing of various data, such as the calculation of enthalpy, glass transition temperature, oxidation induction period, melting point and crystallization of substances, etc.


FAQ
QI want to measure the melting point and crystallization temperature of polymer materials. Is Huicheng DSC-600S suitable?
A Yes! This DSC-600S uses imported high-Sensitivity Sensors, which can accurately capture the melting endothermic peak and crystalline exothermic peak of polymer materials during the heating process. Its temperature accuracy reaches 0.001 ° C and DSC resolution is 0.01 μW, which can clearly distinguish subtle thermal effect changes and is suitable for studying the phase transition behavior of polymer materials.
QLaboratories often require different heating procedures and atmosphere conditions. How flexible is the temperature control of this instrument?
A The temperature control of the DSC-600S is very flexible, it supports 12-order program temperature control, the heating rate is adjustable from 0.1 to 100 ° C/min, and there are two experimental modes of FTC and STC. The atmosphere system can be intelligently set by software to automatically switch between two gases, which can meet your different experimental needs, whether it is complex thermal analysis or conventional Quality control is very suitable.
QI want to measure the melting point and crystallization temperature of polymer materials.
A Recommended Huicheng DSC-600S Differential Scanning Calorimeter, using imported high Sensitivity Sensors, can accurately measure the thermal effect changes in the melting and crystallization process, temperature accuracy of 0.001 ℃, suitable for the study of polymer materials.
QLaboratory to do material thermal stability analysis, how to select the function?
A It is recommended to choose Huicheng DSC-600S. With two experimental modes of FTC and STC, the temperature control is more accurate and flexible, and it can measure oxidation induction period and thermal stability parameters. 12-order program temperature control and dual-channel atmosphere automatic switching function can meet the needs of various complex experimental conditions.