Huicheng DSC-600L/-170~600 Differential Scanning Calorimeter -170 ℃~ 600 ℃

SE
Liquid nitrogen refrigeration (fully automatic)
$9802.00/set
PromotionLoading...
Coupon
Certificate

HuiCheng DSC-600L/-170~600 Differential Scanning CalorimeterSPEC

HuiCheng DSC-600L/-170~600 Differential Scanning CalorimeterDetails

HuiCheng DSC-600L/-170~600 Differential Scanning CalorimeterPacking list

SKU
NB048381
DSC range
0~±2000mW
temperature range
-170 ℃~ 600 ℃ liquidnitrogen refrigeration (automatic pressurization)
Timer frequency
16.6Hz
Heating rate
0.1~100℃/min
Cooling rate
0.1~50℃/min
Temperature Accuracy
0.001℃
Temperature Resolution
0.01℃
Temperature Fluctuation
±0.01℃
Temperature, repeability
±0.01℃
DSC noise
0.001mW
DSC resolution
0.01μW
DSC Accuracy
0.001mW
DSC sensitivity
0.001mW
experimental mode
FTC, STC mode can be set arbitrarily
programmed temperature control
Flexible setting of 12-step temperature control in all stages
Temperature control method
Heating, thermostatic, cooling
scan type
Heating, cooling, isothermal scanning
atmosphere control
The atmosphere of the two channels can be set freely, and the instrument can be automatically switched
gas flow rate
0~200mL/min
gas pressure
0.2Mpa
display mode
24Bit color 7-inch LCD touch screen display
Data Interface
Standard USB port
sampling rate
1~ 10Hz programmable setting
Instrument calibrated
The lower computer and the upper computer have multi-point temperature correction function at the same time
parameter standard
Equipped with standard materials, users can adjust the temperature and enthalpy by themselves
Working Voltage
AC220V/50Hz or custom
working power
300W
DSC-600L/-170~600
Differential Scanning Calorimeter
Liquid nitrogen refrigeration (fully automatic)
Huicheng DSC-600L/-170~600 Differential Scanning Calorimeter -170 ℃~ 600 ℃ Picture

As a classical thermal analysis method that can control the thermal effect at program temperature, differential scanning calorimetry (DSC) has been widely used in various occasions such as research and development, process optimization, quality control and failure analysis in various fields of materials and chemistry. Using the DSC method, we are able to study the phase transition of inorganic materials, the melting and crystallization process of polymer materials, the polymorphism phenomenon of drugs, and the solid/liquid phase ratio of foods such as oils and fats.

Instrument Usage

Measure the physical and chemical changes related to heat, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transition reaction heat, thermal stability of the product, curing/cross-linking, oxidation induction period, etc.

Features

  • The integrated design of the whole machine reduces signal loss and interference, greatly improves signal sensitivity and resolution, and can obtain a more stable baseline.

  • Equipped with imported high-frequency core control processor, the operation and processing speed is faster, and the control is more efficient.

  • The imported high-sensitivity sensor is adopted, which effectively improves the sensitivity and accuracy of DSC signal.

  • The independent atmosphere control can be intelligently set by software, and the instrument can automatically switch the gas circuit system, which makes the experimental efficiency higher.

  • The lower computer and the upper computer of the equipment system have multi-point temperature correction function at the same time, which meets the needs of different experimental occasions and improves the accuracy of temperature testing.

  • With two experimental modes of FTC and STC, the temperature control is more friendly and flexible, which can meet the needs of different experiments in different application scenarios, the temperature control of the experimental process is more accurate, and the analysis of sensor signals is more efficient.

  • The full temperature control system adopts the optimized dynamic PID algorithm, which greatly avoids the shortcomings of the traditional PID algorithm and improves the robustness of dual-mode temperature control.

  • The 12-step program temperature control setting makes the experimental methods more diverse.

  • The sampling frequency of the sensor signal can be set to 1~10Hz, the experimental method is more flexible, and the data is more controllable.

  • Dual temperature sensors are independent of each other to measure the furnace temperature and sample temperature separately at the same time.

  • The equipment system can do experiments on heating, cooling and isothermal related materials.

  • The instrument adopts USB two-way communication, supports self-recovery connection, intelligent software design, has the function of deducting the baseline, automatically plots the experimental process, and intelligently realizes the processing of various data, such as the calculation of enthalpy, glass transition temperature, oxidation induction period, melting point and crystallization of substances, etc.


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.