China

HuiNuo RJCS coating Solvent Rub Resistance Tester

In line with GB/T 23989 standard, friction load 1000 +/- 10g, the counter directly displays the number of wipes, wiping stroke 120 +/- 5mm, wiping Frequency 0~60 times/min.
Model:
Certificate

HuiNuo RJCS Resistance to solvent TesterSPEC

HuiNuo RJCS Resistance to solvent TesterDetails

HuiNuo RJCS Resistance to solvent TesterPacking list

SKU
NB048563
friction load
1000 +/- 10g
erasure stroke
120±5mm
Erasure Frequency
0~60 times/min
contact surface diameter
14±0.5mm
test size
75×200mm
Power Supply
220V 50Hz
Dimension
260×260×340mm
Weight
About 20kg
Wiping pressure on the test plate
0.06Mpa
RJCS
Resistance to solvent Tester
In line with GB/T 23989 standard, friction load 1000 +/- 10g, the counter directly displays the number of wipes, wiping stroke 120 +/- 5mm, wiping Frequency 0~60 times/min.
HuiNuo RJCS coating Solvent Rub Resistance Tester Picture

Introduction to the device

The solvent resistance wipe meter is a device used to determine the solvent wipe resistance of coatings, and the standard GB/T 23989 is implemented. A wiping head with a certain speed and wiping pressure (absorbent cotton wetted with solvent in contact with bread) is used to reciprocate on the surface of the specimen, and the number of wipes can be directly read by the counter, and the solvent resistance of the coating can be evaluated according to the number of wipes required for the coating to break.

Instructions

1. Unscrew the set bolts on the specimen grips at both ends, place the 75×200mm specimen under the fixing plate, and then tighten the set bolts.

2. Take an appropriate amount of absorbent cotton and wrap it on the contact surface of the wiping head, install the hoop piece, tighten the fixing screw, then take an appropriate amount of absorbent cotton, put it into the inner cavity of the wiping head, drip in an appropriate amount of solvent until the wiping head has solvent seepage, and then place the wiping head on the sliding arm.

3. Plug in the power supply, set the number with the setter, and select the number of times you want to wipe; Turn the speed control knob to select the desired wiping speed (60 times/min is recommended, that is, the speed control knob points to MAX).

4. Turn on the power switch of the governor, the machine starts to work, and after reaching the predetermined number of times, the machine will automatically stop and take off the sample for observation.

5. If you want to stop the machine during operation, you can directly turn off the power switch of the governor, and then turn on the power switch of the governor if you want to continue to work.

6. After the machine stops automatically, you only need to press the "Clear" button on the number setter, and the machine can run again.


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard