China

GUOYUGRA GY/VGD-200-CO-G (0-1000ppm) Hydrogen Resistance, Carbon Monoxide Detector

SE
Fully anti-hydrogen interference, High Sensitivity Smart Sensors and Low Power MCU chip design, support multiple signal outputs, custom wireless transmission options, rugged aluminum alloy explosion-proof housing.
$518.00/set
PromotionLoading...
Coupon

GUOYUGR GY/VGD-200-CO-G (0-1000ppm) hydrogen resistance Carbon monoxide DetectorSPEC

GUOYUGR GY/VGD-200-CO-G (0-1000ppm) hydrogen resistance Carbon monoxide DetectorDetails

GUOYUGR GY/VGD-200-CO-G (0-1000ppm) hydrogen resistance Carbon monoxide DetectorPacking list

SKU
NB048677
detection medium
CO
receiving device
User computer, control alarm, PLC, DCS, DDC, etc
Operating Mode
diffusion
Detection principle
Catalytic combustion
detection range
0-500ppm(1000ppm、2000ppm、5000ppm、10000ppm)
resolution
0.1
detection error
≤ +/- 3% F. S (≤ 3% in full scale)
repeatability
≤±2%
Linearity
≤±2%
Response time
≤30S
Operating Voltage
DC24V( 12V ~30V)
Operating temperature
-20 ℃~ 50 ℃ (Special requirements: (-40 ℃~ + 70 ℃)
Operating humidity
10-95% RH (non-condensing)
Sensors Life
2 to 3 years (depending on the environment used)
Explosion-proof form
Probe Transmitters and Sensors are flameproof.
Connecting cable
① 4~ 20mA choose three-core Shielding cable, RS485 choose four-core, when the distance exceeds 1000 meters (with a Detector), the single Wire diameter is ≥ 1.5mm, and the Shielding layer is connected to the earth. ② Wireless transmission: can be built-in LORA, Zigbeg module, short-range wireless transmission; can be external GPRS/4G module, remote data transmission to cloud platform, can view history on computer and mobile phone, no distance limit (optional)
Alarm mode
On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, etc
Alarm settings
Standard configuration Two-level alarm; Alarm mode can be set: conventional high and low alarm, interval control alarm
Dimension
182*201*92( L*W*H)
electrical interface
Default M20X1.5 internal thread, optional 3/4NPT, 1/2NPT
Measurement Certificate
Optional, user pays
Optional Accessories
220V to 24V power adapter. Computer monitoring accessories: free host computer software, USB to RS485 conversion cable, RS485 to network port converter
Output signal 1
① 4-20mA signal: standard 12-bit Accuracy 4-20mA output chip, transmission distance 1Km; ② RS485 signal: using standard MODBUS RTU protocol, transmission distance 1Km
Output signal 2
③ Voltage signal: 0.4-2 V, 0-5V, 0-10V output, optional (Voltage output and current output choose one); ④ Switching signal: standard 1 group of passive touchpoint relays, Capacity 220VAC 3A/24VDC 3A; ⑤ GPRS, 4G, WI FI, LORA, ZigBee and other wireless signals
GY/VGD-200-CO-G (0-1000ppm) hydrogen resistance
Carbon monoxide Detector
Fully anti-hydrogen interference, High Sensitivity Smart Sensors and Low Power MCU chip design, support multiple signal outputs, custom wireless transmission options, rugged aluminum alloy explosion-proof housing.
GUOYUGRA GY/VGD-200-CO-G (0-1000ppm) Hydrogen Resistance, Carbon Monoxide Detector Picture

Introduction

The gas concentration Detector is a low-power modular design with MCU chip, intelligent sensor detection technology, integral flameproof (d) structure, and fixed installation method. The standard configuration is LCD tft high-definition liquid crystal display, three-wire 4~20mA analog, RS485 digital and switching signal output, providing customized products according to user needs, and also supporting output signal fine-tuning and other functions, which is convenient for system networking and maintenance.

Enforce the standard

  • GB/T3836.1-2021 "Explosive atmospheres Part I: General requirements"

  • GB/T3836.31-2021 "Explosive atmospheres Part 31: Equipment protected by anti-dust ignition enclosure "t"

  • GB3836.15-2000 "Electrical Equipment for Explosive Gas Atmospheres Part 15: Electrical Installation in Hazardous Locations (Except Coal Mines)"

  • GB12476.1-2013 "Electrical Equipment for Combustible Dust Environments Part 1: General Requirements" GB12358-2006 "General Technical Requirements for Workplace Ambient Gas Detection and Alarm Instruments"

  • GBZ2.1-2007 "Occupational Exposure Limits for Hazardous Factors in the Workplace"

  • GB4208-2008

Features

  • The use of customizable range intelligent sensors ensures the advantages of high sensitivity, high precision, stable linearity, and fast response of the Detector.

  • The MCU chip is used, which highlights the low power consumption, safe and reliable performance, accurate data conversion, and stable signal output of the Detector. 4-20mA, RS485, switching and other signal outputs, easy to access PLC, DCS, DDC and other industrial control systems, can also be linked to fans, solenoid valves and other control equipment through switching units;

  • Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.;

  • Dot matrix high-definition LCDTFT LCD screen, Chinese and English operation interface can be switched by itself;

  • The Detector can be operated by remote control without opening the cover, such as alarm value, zero adjustment, calibration, reset, modification of address code and other function menus;

  • Local integrated sound and light alarm indication can realize remote mobile phone, computer, monitoring room, third-party platform and other alarm prompts through alarm control host or wireless signal, and can also be infrared remote control one-key silencing;

  • Aluminum alloy cast explosion-proof shell, strong and durable;

  • It has passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications.

  • Explosion-proof certificate level: Ex db IIC T6 Gb;

  • Explosion-proof certificate number: SYEx23.04100.

Product Dimension Drawing

Guoyu Technology GY/VGD-200-CO-G (0-1000ppm) Anti-Hydrogen Carbon Monoxide Detector Details Figure 1

Product installation recommendations

Guoyu Technology GY/VGD-200-CO-G(0-1000ppm) Anti-Hydrogen Carbon Monoxide Detector Details Figure 2

Gas types and capacities are available

GY/VGD-200 host other measurable toxic gas list
The name of the gasmolecular formulaMeasuring range (ppm)The name of the gasmolecular formulaMeasuring range (ppm)
carbon monoxideCO0-200/1000/2000SilanesS IH40-20/50
oxygenO20-25%/30%/100%hydrogen peroxideH2O20-50/100/2000
hydrogen sulfideH2S0-50/100/200/500phosgeneCOCL20-1
hydrogenH20-1000/2000/40000chlorine dioxideCLO236545
sulfur dioxideSO20-20/100/200/2000FluorineF20-1
nitrogen dioxideNO20-20/100/2000TetrahydrothiopheneC4H4S0-50 mg/m3
nitric oxideNO0-20/100/2000Hydrogen selenideSEH20-5
chlorineCL20-20/200hydrogen fluorideHF0-10
hydrogen chlorideHCL0-20/50/200Methyl mercaptanCH3SH0-10
flammabilityEX0-1/5/100/2000carbon dioxideCO20-2000/5000/10000
formaldehydeCH2O0-10/50/100ethyleneC2H40-10/20/100/2000
ethylene oxideC2H4O0-10/50/100/500Hydrogen bromideHBR0-20/200
hydrazineN2H40-1BromineBR20-20/200
ammoniaNH30-50/100/1000Hydrogen arsenicASH30-1
flammabilityEX0-20/30/100ozoneO30-1/5/10/50/100/200
Sulfur hexafluorideSF60-1000 ,2000EthylboraneB2H60-1
freonCFC/R5070-1000/2000RefrigerantRX0-2000/5000
freonR12/R220-1000/2000freonR113/R1140-1000/2000
freonR125/R2900-1000/2000freonR134a/R404a0-1000/2000


FAQ
QWhat instruments need to be selected to monitor carbon monoxide concentration in a chemical plant?
A GY/VGD-200-CO-G (0-1000ppm) anti-hydrogen carbon monoxide detector. Designed for industrial environments, it adopts flameproof structure and meets explosive environment safety standards, which can reliably monitor carbon monoxide concentration from 0-1000ppm. Its 4-20mA and RS485 outputs can be easily connected to the PLC or DCS system of the chemical plant to realize real-time monitoring and alarm to ensure safe production.
QGas detectors with high safety certification and remote monitoring?
A GUOYUGRA's carbon monoxide detector has passed various international safety certifications such as CMA, CNAS, CE, ROHS, SIL, UL, ECM, etc. Explosion-proof level reaches Ex db IIC T6 Gb. Support GPRS, 4G, WiFi and other wireless transmission, can realize remote mobile phone and computer monitoring, and has infrared remote control silencing and sound and light alarm functions, suitable for places that require high safety standards and remote management.
QGas detection equipment with multiple signal outputs and customizable ranges is required. What is recommended?
A GUOYUGRA's GY/VGD-200 provides 4-20mA analog, RS485 digital, switching volume and a variety of wireless signal output, compatible with PLC, DCS and other systems. Sensors range can be customized (such as CO support 0-2000ppm), high accuracy (error ≤ +/- 3% F. S), and support remote control calibrate and alarm settings, flexible functions, suitable for diverse industrial inspection needs.
Standard