China

Factory Direct HYQ-Z-102 manual Contact Angle Analyzer contact angle Tester

SE
Contact angle measurement range 0 ° -180 °, contact angle measurement accuracy +/- 0.1 °, injection system moves up and down 35mm, left and right 35mm, test sample table size is about 200mm × 125mm, Microscope moves up and down 80mm (fine-tuning 3mm), injection system Manual injection system (knob type)
$2465.00/set
PromotionLoading...
Coupon
Model:

Factory HYQ-Z-102 Manual Contact Angle AnalyzerSPEC

Factory HYQ-Z-102 Manual Contact Angle AnalyzerDetails

Factory HYQ-Z-102 Manual Contact Angle AnalyzerPacking list

SKU
NB049336
Contact angle Measurement Range
0~180°
Return contact angle measurement Accuracy
±0.1°
Contact angle test method
Automatic fitting measurement, baseline fitting measurement, manual three-point measurement, area measurement method
Contact angle analysis method
Automatic analysis of contact angle and manual point measurement
Injection system movement
35mm up and down, 35mm left and right
Test sample Countertop size approx
200mm×125mm
Sample stage movement
Left and right 100mm front and rear 40mm
Microscope movement
Up and down 80mm (fine-tuning 3mm)
Sampling system
Manual injection system (knob type), Micrometer control size, direct injection of liquid, no need to go through the pipeline, avoid bubbles, cleaning and other problems
Microscope
0.7-4 High Definition Microscope
scope
Directly convert the measured contact angle to calculate the surface tension or surface energy (range: 0~60mN/m)
data preservation
Automatically save measurement data and pictures, view and delete historical test data. Instant screenshots; export any picture sheet
Maximum sample size
300Mm (length) × 150mm (width) × 10mm (thickness)
Dimensions
About 500 * 200 * 550mm
Power Supply
220V
HYQ-Z-102
Manual Contact Angle Analyzer
Contact angle measurement range 0 ° -180 °, contact angle measurement accuracy +/- 0.1 °, injection system moves up and down 35mm, left and right 35mm, test sample table size is about 200mm × 125mm, Microscope moves up and down 80mm (fine-tuning 3mm), injection system Manual injection system (knob type)
Factory Direct HYQ-Z-102 manual Contact Angle Analyzer contact angle Tester Picture

Product description

HYQ-Z-102 Manual Contact Angle Tester for Measuring Solids. The contact angle between the three phases of a liquid and a gas. By measuring the contact angle, the adhesion of the liquid to the solid, the surface tension of the solid and the surface energy of the solid are calculated and measured. The instrument is widely used in petroleum, chemical, pharmaceutical, papermaking, dyes and various new materials research and manufacturing fields. Microcontrol technology is used to transfer the ingested images into a computer for saving, analysis, and printing. The speed is fast, the data is accurate, and the operation is convenient.

Product principle

The contact angle is defined as the angle between the gas-liquid interface and the solid-liquid interface at the interface of solid, liquid and gas, and the contact angle is the scale that shows the humidity of the solid surface, which is determined by using most of the solid droplets, and the low contact angle indicates that the humidity is high (hydrophilic) and the surface is easy to paste. The contact angle of the liquid in contact with a flat solid surface is determined by the end point of the water droplet curve in the liquid-solid-gas junction and the contact point of the solid surface.

Software Introduction

Software function introduction and test method: The Contact Angle Analyzer software is designed with Windows operation interface structure. Beautiful and novel, simple and generous operation. It is clear to the user at a glance, and the main function keys are all placed in the toolbar at the top of the interface. It is very easy to select the operator. Functions that are not commonly used are placed in the submenu of the processing bar in the toolbar, and the operator can extract and use them according to the experimental requirements.

Before starting the test, connect the power supply of the computer and monitor. Plug in the power supply behind the light source box of the instrument host. Turn on the computer, double-click the contact angle software icon on the computer screen, the contact angle software will open, and the following interface will appear.

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.