DZ-DSC400 is a high-precision differential scanning calorimeter launched by the company, the sensor is made of imported material E-couple, high accuracy, high sensitivity, good repeatability, signal acquisition circuit with shielding protection, strong anti-interference, high baseline stability and repeatability.
DZ-DSC400 differential scanning calorimeter can be used to test glass transition temperature, phase transition temperature, melting point, enthalpy value, curing temperature and product stability, specific heat capacity, crystallization, oxidation induction period, etc. It can be competent for the research of pipes, polymers, chemicals, food and many other fields, and the products serve universities, enterprises, scientific research institutes and quality inspection institutions, etc., with a wide range of applications to meet the testing needs of various industries.
1. Industrial-grade 7-inch touch screen with rich display information
2. Brand new furnace structure, better baseline and higher precision. The heating adopts indirect conduction mode, which has high uniformity and stability, reduces pulse radiation, and is better than the traditional heating mode.
3. USB communication interface mode, strong versatility, reliable and uninterrupted communication, support self-recovery connection function.
4. Automatically switch between two channels of atmosphere flow, fast switching speed and short stability time. At the same time, a shielding gas input is added.
5. The software is rich in functions and covers the corresponding test case database
6. Ultra-high sensitivity, accuracy, 0.001MW

GB/T 33466.1-2016 Rigid polyvinyl chloride pipes -- Differential scanning calorimetry (DSC) Part 1: Measurement of processing temperature
GB/T 40271-2021 Test methods for textile fiber identification -- Differential scanning calorimetry
GB/T 19466.1-2004 Plastics – General principles for differential scanning calorimetry (DSC).
GB/T 19466.4-2016 Plastics – Differential scanning calorimetry (DSC) – Part 4 - Determination of specific heat capacity
GB/T 19466.5-2022 Plastics – Differential scanning calorimetry (DSC) – Part 5: Determination of characteristic reaction curves temperature, time, reaction enthalpy and conversion rate
GB/T 19466.6-2009 Plastics – Differential scanning calorimetry (DSC) – Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT).
GB/T 19466.2-2004 Plastics – Differential scanning calorimetry (DSC) – Part 2: Determination of glass transition temperature
GB/T 19466.3-2004 Plastics – Differential scanning calorimetry (DSC) – Part 3: Determination of melting and crystallization temperature and enthalpy
GB/T 29611-2013 Determination of glass transition temperature of raw rubber (part of the national standard display)