China

DZDR-AS transient method thermal conductivity Tester, transient plane heat source method

SE
Using the international standard transient plane heat source method (ISO 2 2007-2, etc.), it can quickly (≤ 160 seconds) and accurately (accuracy 0.0001W/(m · K)) measure the thermal conductivity of various materials (solid, liquid, powder, etc.).
Model:
Certificate

DaZhan equipment DZDR-AS Transient thermal conductivity TesterSPEC

DaZhan equipment DZDR-AS Transient thermal conductivity TesterDetails

DaZhan equipment DZDR-AS Transient thermal conductivity TesterPacking list

SKU
NB049697
test range
0.0001—50W/(m*K)
Measurement temperature range
-40 ℃ - 200 ℃ (expandable)
Test probe
High Accuracy probe 2, optional anti-magnetization probe
Accuracy
0.0001W/(m*k)
Repeatability Error value
≤1%
Measurement time
≤160S
Overall power
<300W
Solid Sample Specifications
No. 1 probe sample size ≥ 7.5mm * 7.5mm * 3.75mm, No. 2 probe sample size ≥ 15mm * 15mm * 7.5mm
Liquid and powder sample specifications
Matching sample holder, Capacity: 18ml
DZDR-AS
Transient thermal conductivity Tester
Using the international standard transient plane heat source method (ISO 2 2007-2, etc.), it can quickly (≤ 160 seconds) and accurately (accuracy 0.0001W/(m · K)) measure the thermal conductivity of various materials (solid, liquid, powder, etc.).
DZDR-AS transient method thermal conductivity Tester, transient plane heat source method Picture

Product Introduction

The DZDR-AS is an accurate, fast and easy-to-use thermal conductivity measuring instrument for measuring the thermal conductivity of thermal insulation materials.

Based on ISO 22007-2-2008, GB/T 32064-2015, GB/T42919.1-2023 and other standards, it can meet the test of different forms of materials, such as liquid, solid block, paste, powder, film, etc., with a short test time, and the test time of each sample is ≤ 160S; The test sensitivity is high, which can reach 0.00001;

Measuring principle

The transient planar heat source method is based on the principle of planar one-dimensional unsteady thermal conduction: the plane heat source in the infinite medium generates a dynamic temperature field inside the medium after receiving the instantaneous heating pulse in the initial thermal equilibrium state, and the thermal conductivity and thermal diffusion coefficient of the sample are calculated by fitting the temperature data generated by the heat conduction process and fitting the function curve. During the test, a constant direct current is applied to the heat source, and the temperature rise on the surface of the heat source increases, and the resistance increases, so that the bridge test system is unbalanced and produces potential changes. By the amount of change in the electrical parameter, the function of temperature increase over time is obtained.

Dazhan Instrument DZDR-AS Transient Method Thermal Conductivity Tester Details Figure 1


FAQ
QThermal conductivity measurement of insulation
A The instrument is specially designed for accurate and rapid measurement of thermal conductivity values of insulation materials, with short test time (≤ 160 seconds per sample) and high Sensitivity (up to 0.00001), which fully meets the requirements of insulation material testing.
QWhich instrument can quickly test the thermal conductivity of a variety of materials?
A The DZDR-AS transient method Thermal conductivity tester adopts the transient plane heat source method, which is characterized by short test time (≤ 160 seconds), which can quickly process various forms of materials such as liquid, solid block, paste, powder, film, etc., greatly improving the test efficiency.