Using the international standard transient plane heat source method (ISO 2 2007-2, etc.), it can quickly (≤ 160 seconds) and accurately (accuracy 0.0001W/(m · K)) measure the thermal conductivity of various materials (solid, liquid, powder, etc.).
Using the international standard transient plane heat source method (ISO 2 2007-2, etc.), it can quickly (≤ 160 seconds) and accurately (accuracy 0.0001W/(m · K)) measure the thermal conductivity of various materials (solid, liquid, powder, etc.).
Product Introduction
The DZDR-AS is an accurate, fast and easy-to-use thermal conductivity measuring instrument for measuring the thermal conductivity of thermal insulation materials.
Based on ISO 22007-2-2008, GB/T 32064-2015, GB/T42919.1-2023 and other standards, it can meet the test of different forms of materials, such as liquid, solid block, paste, powder, film, etc., with a short test time, and the test time of each sample is ≤ 160S; The test sensitivity is high, which can reach 0.00001;
Measuring principle
The transient planar heat source method is based on the principle of planar one-dimensional unsteady thermal conduction: the plane heat source in the infinite medium generates a dynamic temperature field inside the medium after receiving the instantaneous heating pulse in the initial thermal equilibrium state, and the thermal conductivity and thermal diffusion coefficient of the sample are calculated by fitting the temperature data generated by the heat conduction process and fitting the function curve. During the test, a constant direct current is applied to the heat source, and the temperature rise on the surface of the heat source increases, and the resistance increases, so that the bridge test system is unbalanced and produces potential changes. By the amount of change in the electrical parameter, the function of temperature increase over time is obtained.
Packing list:
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
QThermal conductivity measurement of insulation
A
The instrument is specially designed for accurate and rapid measurement of thermal conductivity values of insulation materials, with short test time (≤ 160 seconds per sample) and high Sensitivity (up to 0.00001), which fully meets the requirements of insulation material testing.
QWhich instrument can quickly test the thermal conductivity of a variety of materials?
A
The DZDR-AS transient method Thermal conductivity tester adopts the transient plane heat source method, which is characterized by short test time (≤ 160 seconds), which can quickly process various forms of materials such as liquid, solid block, paste, powder, film, etc., greatly improving the test efficiency.