Netherlands

TQC VF2020 Viscosity Cup standard DIN 53211 for measurement of viscosity of paints, varnishes and other liquids (filter to be purchased separately)

SE
Viscosity cup DIN 53211 for int. Variable nozzle
$397.00/piece
PromotionLoading...
Coupon
Model:
Certificate

TQC sheen VF2020 Viscosity cupSPEC

TQC sheen VF2020 Viscosity cupDetails

TQC sheen VF2020 Viscosity cupPacking list

SKU
NB000506
flow hole diameter
1/2/3/4/5/6/7/8mm
Capacity
100ml
Cup body material
Titanium anodic oxidation aluminum
Filter material
stainless steel
Applicable standards
Approximate DIN 53211
Ambient Temperature
25±0.2℃
Certificate
without
Weight
226g
VF2020
Viscosity cup
Viscosity cup DIN 53211 for int. Variable nozzle
TQC VF2020 Viscosity Cup standard DIN 53211 for measurement of viscosity of paints, varnishes and other liquids (filter to be purchased separately) Picture

Introduction to VF2020 Viscosity Cup

The TQC VF2020 Viscosity Cup is a Viscosity Cup with a filter tip diameter of 4mm, also known as the No. 4 Viscosity Cup. It is produced and designed according to the DIN 53211 standard. It is an aluminum Viscosity Cup with a filter tip holder. The filter tip can be freely replaced with other aperture. The cup body of the VF2020 Viscosity Cup is made of titanium anodized aluminum, and the cup spout holder and cup spout are made of stainless steel, which has good wear resistance. The VF2020 Viscosity Cup is used to measure the viscosity of paints, varnishes and other liquids.

The special aluminum Viscosity Cup is equipped with a stainless steel filter positioner, which can replace stainless steel filters with apertures of 1mm-8mm. Stainless steel filters must be ordered separately. The internal dimensions of the replaceable filter Viscosity Cups are similar to those specified in DIN53211.

TQC Viscosity Cup DIN 53211 can be used with a bracket. It is a special Viscosity Cup for laboratories. The bracket needs to be purchased separately .

Note: The filter tip of the VF2020 Viscosity Cup needs to be purchased separately.

Features

1. The design of the annular groove at the mouth of the cup can store spilled liquid.

2. The overall dimensions are designed so that they can be matched with the TQC  VF2020 Viscosity Cup holder.

3. Easy to clean. There are no indentations in the structure of the cup wall and outflow hole that are difficult to clean.

4. The production of TQC Viscosity Cups has consistent quality control.

5. Each Viscosity Cup is engraved with a unique serial number.

Actual pictures

VF2020 replaceable filter Viscosity Cup actual photo 1

VF2020 replaceable filter Viscosity Cup actual photo 2

VF2020 replaceable filter actual photos

VF2020 replaceable filter Viscosity Cup actual photo 3

Dutch TQC Viscosity Cup automated production process

Dutch TQC Viscosity Cup standardized production process

Outflow hole list

VF2020 - Aluminum DIN 53211 Viscosity Cup (with spout positioner)

Cup spout:

VF2181 - 1 mm diameter outflow hole (approx. DIN 53211)

VF2022 - 2 mm diameter outflow hole (approx. DIN 53211)

VF2023 - 3 mm diameter outflow hole (approx. DIN 53211)

VF2024 - 4 mm diameter outflow hole (according to DIN 53211), calibrated with oil of standard viscosity.

VF2025 - 5 mm diameter outflow hole (approx. DIN 53211)

VF2026 - 6 mm diameter outflow hole (approx. DIN 53211)

VF2027 - 7 mm diameter outflow hole (approx. DIN 53211)

VF2028 - 8 mm diameter outflow hole (approx. DIN 53211)

VF2181VF2022VF2023VF2024
VF2181 filterVF2022 filterVF2023 filterVF2024 filter
VF2025VF2026VF2027VF2028
VF2025 filterVF2026 filterVF2027 filterVF2028 filter

Instructions

According to the standard, the temperature of the liquid to be tested is 25 degrees Celsius, and the temperature fluctuation needs to be minimal during the test and cannot exceed +/-0.2 degrees Celsius.

Adjust the temperature of the liquid to be measured if necessary.

According to the specification table and the expected viscosity range of the liquid to be measured, select a Viscosity Cup with an appropriate aperture (select the VF2020 Viscosity Cup ).

Adjust the Viscosity Cup so that it is in a horizontal position (Viscosity Cup holder and bubble level indicator are recommended). Then cover the outflow hole and put the liquid to be tested

Inject the VF2020 Viscosity Cup so that the curved surface of the liquid is above the edge of the cup.

Use a glass suction plate to move the liquid curved surface into the overflow ring and close the Viscosity Cup.

The distance between the outflow hole of the Viscosity Cup and the liquid level of the recovered sample needs to be greater than 100 mm. Open the covered outflow hole and remove the glass extractor. Timing time from

Start by removing the glass pumping plate and end when the liquid stream breaks for the first time.

Maintenance measures

It is especially important to clean the outflow hole to remove residue and avoid scratching its inner surface.

Although the Viscosity Cup is designed to be sturdy, it is a precision instrument and must not be dropped or hit.

Need to be cleaned after use.

Please use a soft cloth to clean the VF2020 Viscosity Cup . Do not use wire brushes or sandpaper. Because this will cause damage similar to that caused by corrosive cleaning agents

Long-lasting damage.

Never hit the spout directly when removing it. Please use the pin provided with the Viscosity Cup to hold the cup mouth, and then tap it with a heavy object (such as a paper weight).

Before installing the cup spout, make sure the cup spout and VF2020 Viscosity Cup are clean.

When not in use, please return the Viscosity Cup to the box.

We recommend annual calibration.

TQC Viscosity Cup selection table

Dutch TQC Viscosity Cup selection table 1

Maximum and minimum viscosity values ​​for TQC Viscosity Cups

Take you into the Dutch TQC

The historical development of TQC company

TQC automated production and strict quality control

TQC R&D team

FAQ
QDo you have the viscosity cup required by DIN53211 standard?
A This VF2020 viscosity cup will do.
QIs the filter of this viscosity cup made of stainless steel?
A Hello, yes.
QWhat is the standard filter diameter of this viscosity cup?
A Hello, the filter diameter of this VF2020 viscosity cup is 4mm.
QYou need din 53211 standard, and the brand is not limited, but I don't know the specific viscosity range and model. Is it this viscosity cup called No. 4?
Standard