âThe innovative and patented fully intelligent control system adopts a fully automatic embedded microcomputer integrated control system (ARM9 high-end processor), a true-color TFT LCD touch screen, and a graphical human-machine interface. The operation is simple, convenient and fast, bringing the user closer. Just like using a smartphone;
âOnline display of real-time operation data of water production and water intake in the whole system (raw water quality, temperature, pressure, third-level water quality, third-level water intake volume/raw water flow rate, ultrapure water quality, ultrapure water intake volume/water intake rate, Water Tank Dynamic display of water volume and level). System data self-analysis and comparison, trend prediction, and preventive reminders to avoid experiments being interrupted without warning;
âTertiary water/ultrapure water can be taken out quantitatively respectively. The range of quantitative water taking is any integer volume, with an error of ±2ml (<500ml) or 1% (â¥500ml);
âTwo-stage reverse osmosis, patented special depth desalination treatment technology, ensures stable output of pure water quality â¤5 us/cm@25℃;
âAll monitoring data of the whole system are collected and recorded in real time, without the need for external computer storage, and the data within one year can be directly queried on the water machine;
âCloud service system. Data is collected and stored in real time. Users can directly export the data from the device through a USB flash drive, and upload it to the Aikopu cloud service center via the network every month for backup and diagnosis, and then trace it back to Aikopu professional engineers. Analyze the uploaded data and provide diagnostic reports and preventive maintenance recommendations to users based on the analysis results;
âPatented sterile water storage tank for easy cleaning and disinfection;
âABS casing, anti-corrosion, safety insulation performance meets GLP safety requirements.

1. Important parts are imported with original packaging, and the materials comply with the standards of the American NSF and Water Quality Association;
2. Standardized module design and production makes product maintenance more secure;
3. The "preventive maintenance" after-sales service system, combined with the Ecopu EMOAS network management platform, computerizes the historical operating status of the equipment to ensure long-term stable operation of the equipment.
Glass dish cleaning, titrator, autoclave, biochemical oxygen demand, heating pot, hydrogen generator, hydroponics, Kedar analysis, stability test, wind erosion resistance Tester, chemical oxygen demand, dissolution test , gene chip analysis, particle analyzer, pH value measurement, surface tension experiment, animal water, aquarium and other basic physical and chemical experiment water.
Serial number | name | Model specifications | quantity | unit | Remark |
1 | PP fiber filter | Supporting | 1 | set | Aquapro |
2 | activated carbon filter | Supporting | 1 | set | Aquapro |
3 | booster pump | Supporting | 1 | set | Aquapro |
4 | RO membrane module | Water production: 10 L/h | 1 | set | Aquapro |
5 | Patented sterile pure water storage device | 10L | 1 | set | AIC |
6 | Pump | Supporting | 1 | set | Aquapro |
7 | purification column | Supporting | 1 | set | Aquapro |
8 | terminal filter | 0.22um | 1 | set | Sartorius |
9 | SMART-ANGEL Fully intelligent monitoring system | Supporting | 1 | set | AIC |
10 | touch system | Supporting | 1 | set | AIC |
| model | AD2L-05-OR | AD2L-05-CE | AD2L-05-BE | AD2L-10-OR | AD2L-10-CE | AD2L-10-BE |
| application | Basic physical and chemical experiments | Physical and chemical experiments | Biological experiments | Basic physical and chemical experiments | Physical and chemical experiments | Biological experiments |
| Pure water production | 5L/H | 10L/H | ||||
| Ultrapure water resistivity | 18.2MΩ.cm | |||||
| Pure water conductivity | 1-5us/cm | |||||
| Total organic carbon TOC | - | <10ppb | <5ppb | - | <10ppb | <5ppb |
| bacteria | - | <1CFU/ml | - | <1CFU/ml | ||
| Bacterial endotoxin | - | - | <0.001EU/ml | - | - | <0.001EU/ml |
| particulate matter | <1 piece/ml | |||||
| Inorganic ion removal rate | â¥99.5% | |||||
| heavy metal ion | â¤0.1ppb | |||||
| Silicon removal rate | ï¼99% | |||||
| Incoming water source | Municipal tap water, conductivity <1000 µS/cm@25℃, total hardness <200ppm, pH: 6.5-8.5, residual chlorine <1ppm, pressure: 0.2MPa-0.5MPa, temperature: 5-35℃. | |||||
| power supply | 220V/50Hz, 250W | |||||
| Dimensions | 395*535*580mm | |||||
| Application-BE | Cell culture, nuclease-free applications, polymerase chain reaction, DNA sequencing, electrophysiology, endocrine blockade analysis, immunohistochemistry, histology, microbial culture media, nucleic acid electrophoresis, pyrogen-free water, toxicology research, etc. Experimental water. | |||||
| Application - CE | Histology, effective liquid chromatography, ultrahigh pressure liquid chromatography, mass spectrometer, atomic emission spectrometry, protein electrophoresis, capillary electrophoresis, spectrophotometry, gas chromatography analysis, atomic absorption spectrometry, integrated circuits, chromatography mass spectrometry, NP analyzer, TOC Analysis, VOC analysis, Western blot method and other physical and chemical experiments and general biological experiments water. | |||||
| Application - OR | Glass dish cleaning, titrator, autoclave, biochemical oxygen demand, heating pot, hydrogen generator, hydroponics, Kedar analysis, stability test, wind erosion resistance Tester, chemical oxygen demand, dissolution test , gene chip analysis, particle analyzer, pH value measurement, surface tension experiment, animal water, aquarium and other basic physical and chemical experiment water. | |||||