China

Kedian MC-3000D film thickness Measurement Instrument thickness range 10~9000μm

Kedian MC-3000D film thickness Measurement Instrument is a split structure, using the principle of magnetic thickness measurement, MC-3000D Measurement range is 10~9000 μm, accuracy is 0.1 μm, suitable for various nonmagnetic coating platings thickness measurement.
Model:
Certificate

KODIN MC-3000D Coating Thickness GaugeSPEC

KODIN MC-3000D Coating Thickness GaugeDetails

KODIN MC-3000D Coating Thickness GaugePacking list

SKU
NB005738
Measurement principle
Magnetic Induction
Measurement range
10~9000μm
margin of error
±3%
Resolution
0.1μm
probe
Split F probe
statistical function
MAX Maximum, MIN Minimum, Average
Power Supply
2 * AA battery, continuous use time up to 200 hours
Calibrated Certificate
none
system language
Chinese
Display screen
3-Digit LCD digital display
supporting software
none
Machine Weight
360g
Machine size
146*81*30mm
Voltage prompt
Display icon in upper left corner
Storage method
Manually stored measurements
Data storage
100 Measured values, 6 groups
Operating temperature
0~40℃
shutdown mode
The shutdown mode can be manually set.
Keypad
6-Key waterproof, oil-proof keyboard
Relative Humidity
≤90%RH
MC-3000D
Coating Thickness Gauge
Kedian MC-3000D film thickness Measurement Instrument thickness range 10~9000μm Picture

Coating Thickness Gauge selector

Introduction

Kedian MC-3000D paint film thickness measuring instrument is a split structure, using the principle of magnetic thickness measurement, which can easily and non-destructively measure the thickness of non-magnetic coating on ferromagnetic materials, such as zinc, copper, chromium or the thickness of paint, enamel, fiberglass, rubber, spraying, asphalt and other coatings on the surface of steel;MC-3000D Paint Film Thickness GaugeThe unique automatic deviation tracking technology makes the measured value more accurate, the probe is processed according to German process standards, and the new alloy material is used to greatly improve the service life and accuracy of the probe.

PrimacyYes

● Basic measurement mode: regular mode, minimum mode, statistical mode

●Monitoring and measurement mode: the difference can be set, and the upper and lower limit alarm settings can be set

● You can delete and store a single data, a group of data, or all data

●Zero-point calibration, two-point calibration and system calibration can be performed

●The shutdown mode can be set, the backlight is turned on or off, and the factory state can be restored

●Stored values can be printed, and statistical values can also be printed

●There are 6 groups of data stored in groups, and each group stores 100 measurement points

●Stored measurements can be viewed in groups

Product display diagram

Kedian MC-3000D paint Film Thickness Gauge physical drawing

FAQ
QAre all Coating thickness gauges available for testing in the JB/T5946 standard?
A Not necessarily, but this MC-3000D Coating thickness gauge can be considered.
Standard