China

HaiNeng i8 Dual beam of light UV-Visible Spectrophotometer

Model:

Hanon i8 UV-Visible SpectrophotometerSPEC

Hanon i8 UV-Visible SpectrophotometerDetails

Hanon i8 UV-Visible SpectrophotometerPacking list

SKU
NB005907
Light spectrum Bandwidth
1.8nm
Wavelength range
190~1100nm
Wavelength Precision
+/- 0.1Nm (D2 656.1nm ), +/- 0.3nm full band
Wavelength Repeatability
≤0.1nm
Photometric range
0~200%T、-0.3~3.0A、0~9999C
Photometric Precision
±0.2%T
Luminosity Repeatability
≤0.15%T
stray light
≤0.03%T
Noise level
±0.0005A
Stability
±0.0004A/h@500nm
Baseline flatness
±0.001A
Interface
USB port
printout
Parallel mouth
monitor
320 * 240 large screen LCD
Light source
Tungsten lamp, deuterium lamp
Detector
Imported silicon photodiode
Power Supply
AC 220V/50Hz 或 AC 110V/60Hz
Dimensions
625*430*210mm
Weight
28kg
Wavelength Drive
automatic
Scanning speed
High, medium and low gears are optional
i8
UV-Visible Spectrophotometer
HaiNeng i8 Dual beam of light UV-Visible Spectrophotometer Picture

Instrument Features and Functions:


1. Dual-path, dual-beam optical system
2. Both the host and the standard PC kit can independently complete the functions of photometry, quantitative measurement, spectral scanning, kinetics, DNA/protein testing, multi-wavelength testing and data printing, and the PC suite can also realize data processing functions
3. The design of the suspension optical system, strengthen the design of the thickened base plate, and eliminate the impact of vibration or deformation on the optical system
4. 24-bit high-speed, high-precision A/D conversion to improve the sensitivity of the instrument
5. The core components are imported in original packaging
Note: In addition to all the functions above i8, i9 also has the function of automatic adjustment of 5 spectral bandwidths of 0.5/1.0/2.0/4.0/5.0

Technical parameters

1. Wavelength range: 190-1100nm

2. Spectral bandwidth: 1.8nm

3. Wavelength accuracy: ± 0.1nm (D2 656.1nm), ± 0.3nm in the whole region

4. Wavelength repeatability: ≤0.1nm

5. Photometric accuracy: ±0.2%T

6. Photometric repeatability: ≤0.15%T

7. Stray light: ≤0.03%T

8. Stability: ±0.0004A/h (at 500nm)

9. Baseline straightness: ±0.001A

10. Noise level: ±0.0005A

11. Photometric range: 0-200%T, -0.3-3A, 0-9999C

12. Wavelength setting mode: automatic

13. Scanning speed: high, medium and low three gears are optional

14. Data output: USB interface

15. Printout: parallel port

16. Display system: 320*240 bit large screen LCD

17. Light source: original imported tungsten lamp, deuterium lamp

18. Detector: imported silicon photodiode

19. Power supply: AC 220V/50Hz or 110V/60Hz

20. Dimensions: 625*430*210mm

21. Weight: 28kg

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Knowledge
Standard