China

ANGNI AD18 High Speed Mulser Processing capacity 50~1500ml

SE
The ANGNI AD18 high-speed dispersion Mulser is equipped with a working head diameter of 18mm and is suitable for a maximum viscosity of 5000mPa·s. The AD18 is a laboratory high-speed dispersion Mulser.
$1160.00/set
PromotionLoading...
Coupon
Model:
Certificate

AN AD18(18G) High Speed Dispersion MulserSPEC

AN AD18(18G) High Speed Dispersion MulserDetails

AN AD18(18G) High Speed Dispersion MulserPacking list

SKU
NB006866
Rated Voltage
AC220V
Rated Frequency
50/60 Hz
Input Power
710W
output power
430W
Rated torque
12.1 N.cm
Operating Mode
S1 (continuous)
Operation control mode
Speed control turntable
Speed range
13000~34000rpm
Speed regulation mode
6th gear
Restart protection function
Yes
Approved torque
12.0 N.cm
Work head material
SS 316L stainless steel
Adapt work head
8G;10G ;12G ;18G;24G(选购)
Ambient Temperature
≤40℃
Allowable Relative Humidity
≤80%
Dimensions
215*310*720mm
Machine Weight
8kg
Work head specification
18G
Processing Capacity
50~1500mL
Max. Processing Viscosity
5000cp
Rotor maximum linear velocity
15m/s
Maximum immersion liquid height
160mm
Work head specification
18mm
Working head length
242mm
Operating temperature(MAX)
120℃
Work head material
SS 316L
Bearing material
PTFE
Minimum immersion liquid height
45mm
AD18(18G)
High Speed Dispersion Mulser
ANGNI AD18 High Speed Mulser Processing capacity 50~1500ml Picture

Introduction

Ani AD18 high-speed dispersing and emulsifying machine is driven by a miniature high-power high-speed motor imported from Germany. It is suitable for stirring and mixing low to medium and high viscosity liquids in the laboratory, dispersing homogeneous granular materials in liquid media, and breaking tissue cells. The machine is composed of a high-speed motor, a dispersing and homogenizing working head and a machine base. The driving host is made of high-quality engineering plastic and die-casting aluminum alloy as the body, and the running state is stable; the working head is made of high-quality stainless steel, and the experimental application area is wide; the adjustment and control of the operating speed can meet the need to correct the operating speed during the experiment to ensure the effectiveness of the experimental operation. control.

Functional Structure Diagram

Functional structure diagram of Anny AD18 high-speed dispersing and emulsifying machine

Working head parts diagram

Ani AD18 high-speed dispersion and emulsification machine working head parts diagram

Applications

Ani AD18 high-speed dispersing and emulsifying machine is suitable for tissue dispersion in the field of biotechnology, sample preparation in the medical field, enzyme treatment in the food industry, and in the pharmaceutical industry, cosmetics industry, paint industry and petrochemical industry, etc., liquid and liquid, liquid and solid Phase, viscosity lower than 0.2Pa.s, temperature lower than 80 ℃ liquid material experiments. Under the triple action of extrusion in the feed liquid, strong impact and pressure loss expansion, the experimental medium can be refined and mixed more evenly to prevent or reduce delamination with the feed liquid. Such as: (homogenate of dairy products, beverages, cosmetics, pharmaceuticals and other products, soft and broken tissue cells).

Dispersed homogeneous working head

Work head GProcessing capacityLine speedstator
AD18(8G)15~50ml10m/sΦ8mm
AD18(10G)20~100ml11m/sΦ10mm
AD18(12G)30~800ml12m/sΦ12mm
AD18(18G)50~1500ml15m/sΦ18mm
AD18(24G)80~5000ml18m/sΦ24mm
Other parameters
Suitable for maximum viscosity5000mPa.s
Maximum operating temperature120°C
Working head materialSS 316L stainless steel
Working head bearing material PTFE
FAQ
QCan this model be equipped with 2 working heads of different specifications at the same time?
A Yes, the machine comes standard with a workbench, and the other specifications can be purchased together.
QCan solids and liquids be processed simultaneously?
A For liquid/solid mixture homogenization operation (addition mixing), solid powder can only be added after the driving host reaches a high speed, but the addition speed should be controlled to avoid too much solid material entering and causing the host to stall and prevent the machine from malfunctioning. When coarser solid materials are used for homogenization operation, please be sure to crush them before proceeding.
QCan the AD18 (18G) Dispersible Mulser be used to treat 1000mL of slurry with a viscosity of around 4000mPa.s?
A Suitable, the machine has a maximum processing viscosity of 4000mPa.s and a Processing capacity of 50~ 1500mL
QCan high viscosity fluids be handled?
A The material with higher viscosity is dispersed and homogenized, and there is a vacuum in the functional area of the working head, which will lead to the appearance of the stall phenomenon of the driving host and affect the homogenization effect. When the material viscosity is high, the material should be moderately diluted or the capacity of the material should be reduced.
QSolid-liquid mixture homogenization operation steps?
A For liquid/solid mixture homogenization operation (addition mixing), solid powder can only be added after the driving host reaches a high speed, but the addition speed should be controlled to avoid too much solid material entering and causing the host to stall and prevent the machine from malfunctioning. When coarser solid materials are used for homogenization operation, please be sure to crush them before proceeding.
QIs there any requirement for the homogeneous operation time of this instrument?
A Half of the time is about 30 seconds to 5 minutes, and prolonging the time will not have a significant impact on the homogenization effect. For example, complex processes such as the dispersion homogenization process containing some reactions can be completed in about 30 minutes.