HUITAI HGZ-800 light chamber light intensity 0~ 25000Lx optional LED tube

SE
Light level six adjustable, Illumrination degree 0~ 25000Lx, volume 800L, standard 3 brackets, large screen LCD display, multiple sets of data on one screen display.
$5165.00/set
PromotionLoading...
Coupon
Model:
Certificate

HuiTai HGZ-800 light chamberSPEC

HuiTai HGZ-800 light chamberDetails

HuiTai HGZ-800 light chamberPacking list

SKU
NB006909
Temperature range
4~ 50 ℃ (no light); 10~50 ℃ (light)
Temperature Resolution
0.1℃
Temperature Fluctuation
±1.0℃
Input Power
3500W
Environmental temperature
5~30℃
Power supply Voltage
AC 220V 50Hz
Liner size
965*580*1430mm
Dimensions
1475*890*1780mm
Shelf (standard)
3pcs
Illumrination degree
0~25000Lx
Volume
800L
light level
Six-level adjustable
HGZ-800
light chamber
Light level six adjustable, Illumrination degree 0~ 25000Lx, volume 800L, standard 3 brackets, large screen LCD display, multiple sets of data on one screen display.
HUITAI HGZ-800 light chamber light intensity 0~ 25000Lx optional LED tube Picture

Overview

HGZ light Incubator is widely used in microbial tissue cell culture, seed germination, seedling test, plant cultivation, insect and small animal feeding. It can accurately simulate different environmental and climatic conditions.

Features

1. Humanized design

● Large-screen LCD display, multi-group data display on one screen, menu-based operation interface, simple and easy to understand, easy to operate. (Standard)

● Use 134s, 406A fluorine-free refrigerant, effective, energy-saving, and make the environment healthier!

● Mirror stainless steel liner is adopted, the four-corner semi-circular arc design is easy to clean, and the shelf spacing in the box is adjustable.

● Double-layer door structure, good thermal insulation performance, no impact on the temperature in the box when observing the situation in the box.

2. Quality assurance

● The use of international brand compressors, self-developed compressor cooling system, can effectively extend the service life of the compressor.

● JAKEL pipe flow circulation fan is used with a unique design of air duct structure to create a good air circulation system to effectively ensure the temperature uniformity in the box.

● Three-sided light design, T4 Incubator special lamp, effectively ensure the light intensity in the box, no dead ends, no omissions.

● The microcomputer controls the temperature and illumination, and the temperature can be set differently with the presence or absence of light.

● PID control mode, control accuracy and small fluctuation, menu-style operation page, simple and easy to understand, easy to operate.

● With 99 cycles of program, each cycle is divided into 30 segments, each section is 99 hours and 99 minutes of cycle steps, which can meet almost all complex experimental processes.

3. Continuous operation technology

● Long-term continuous operation, continuous working time is not less than 360 hours

4. Independent temperature limit alarm system (optional)

● If the temperature limit is exceeded, the operation will be automatically interrupted, and the operator will be prompted by sound and light alarm. Ensure the safe operation of the experiment without accidents.

5. Convenient data processing (optional)

● With USB or RS485 interface, it can be connected to a printer or computer, and can record the change of temperature parameters. (Optional)

Optional

Intelligent program controller

Independent temperature limiting controller

Embedded printers

RS485 interface and dedicated software

Test hole 25mm/50mm

HGZ series

ModelLight intensity
HGZ-1500~12000Lx six levels adjustable
HGZ-2500~15000Lx six levels adjustable
HGZ-4000~25000Lx six levels adjustable
HGZ-8000~25000Lx 6 levels adjustable (optional LED tube)
Other parameters
Supply VoltageAC220V  50HZ
Temperature control rangeWith light: 10~50°C without light: 4~50°C
Constant temperature fluctuation±1℃
Temperature resolution0.1℃
Cargo carriers3pcs (standard)
Operating Environment5~30℃
Note: The performance parameters are tested under no-load conditions, without strong magnetism and vibration, and the ambient temperature is 20°C, and the ambient humidity is 50%RH.
Non-standard Incubators can be customized according to user needs (the customized product cycle is 30 to 40 working days after the order is confirmed).
FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.