China

FANGRUI BZY-201 Surface Tensiometer manual lifting platform, platinum plate test mode

Platinum plate test; electromagnetic force equilibrating principle; manual labjack, automatic measurement, full scale automatic correction; measurement of interfacial tension between disphase mixed liquids, 0~400mN/m range.
Model:

FangRui BZY-201 Surface TensiometerSPEC

FangRui BZY-201 Surface TensiometerDetails

FangRui BZY-201 Surface TensiometerPacking list

SKU
NB008788
Measurement method
Platinum plate method
Operation mode
Manual lift, automatic measurement
Surface tension Measurement range
0~400mN/m
sensitivity
0.01mN/m
Surface tension Accuracy
±0.05mN/m
Sexual repeability
±0.05mN/m
Display
Wide Viewing Angle backlit LCD
Temperature range
RT or 5~ 90 ℃ (Thermostat and thermostatic cell are required)
Measurement time
Low concentration samples: platinum plate method takes 3 to 5 seconds, platinum ring method takes 40 to 60 seconds
Data Interface
RS 232C Serial or optional USB Data Interface
Dimensions
320*200*340mm
Net Weight
7kg
Power
220V/50Hz
BZY-201
Surface Tensiometer
Platinum plate test; electromagnetic force equilibrating principle; manual labjack, automatic measurement, full scale automatic correction; measurement of interfacial tension between disphase mixed liquids, 0~400mN/m range.
FANGRUI BZY-201 Surface Tensiometer manual lifting platform, platinum plate test mode Picture

Introduction

FANGRUI BZY-201 Surface Tensiometer adopts a high-performance weighing sensor based on the principle of electromagnetic force balance, with accurate measurement and excellent repeatability. Platinum plate method and platinum ring method are used together. Except that the lifting platform is manually operated, the others are the same as the QBZY series automatic surface/interface tensiometer, so it has a very high cost performance.

main feature

1. Platinum plate or platinum ring test principle, simple and convenient operation;

2. Automatic digital measurement reduces human error;

3. Full-scale zero reset: one-key zero reset, complete in an instant, zero zero drift;

4. Full-scale automatic calibration: accurate and reliable data, excellent repeatability;

5. When the platinum plate is tested, the displayed value is the surface/interfacial tension value of the sample, no need to calculate again; when the platinum ring is tested, it has a peak hold function, which needs to be calculated by Excel or automatically converted to the surface/interfacial tension by data processing software value;       

6. The instrument has a compact structure and works independently without any additional equipment (such as an external computer, etc.);

7. It can measure the change of the surface tension of the sample due to different time (especially when there are surfactants or volatile substances, limited to platinum plate test mode);

8. Automatically measure medium and high viscosity liquid samples and get accurate balance results (limited to platinum plate test mode);

9. It can measure the interfacial tension between immiscible liquids such as: oil/water interface; 

10. It can completely replace the traditional mechanical Surface Tensiometer;

11. BZY-201 Surface Tensiometer is similar to the QBZY series in terms of main structure and Specifications except the manual control of the lifting of the sample platform. It has high-quality design, economical price, and high cost performance.


BZY series selection

modeltest mode
BZY-101(BZY-A)platinum plate method
BZY-102(BZY-B)Platinum Ring
BZY-103Plate/ring combined use
Other parameters
Measuring range0-600mN/m
measurement accuracy0.1mN/m
accuracy error0.1mN/m
Repeatability Error0.1mN/m
Sample constant temperature range0-120℃
Wind Shieldnone

modeltest mode
BZY-201platinum plate method
BZY-202Platinum Ring
BZY-203Plate/ring combined use
Other parameters
Measuring range0-400mN/m
measurement accuracy0.01mN/m
accuracy error0.04mN/m
Repeatability Error0.04mN/m
Sample constant temperature range15-60℃
Wind Shieldhave

Pictures

FANGRUI BZY-201 Surface Tensiometer display

FAQ
QIs the measured surface tension dynamic or static?
A The test solvent is static. When the platinum version pulls up the film and breaks, it is the current tension value. The process of film breaking is dynamic.
QYou can directly read the result by putting the liquid of this plate method on it. Do you still need to enter any Density data?
A Direct out of the data, without entering the Density value.
QCan I send samples for testing?
A Sure.
QCoating surface tension measurement, can directly display the data, which one to choose?
A Platinum plate surface tensiometer can.
Knowledge
Standard