China

EYESKY ES10B11-VOC (0~2000ppm) Fixed VOC Gas Detector

EYESKY ES10B11-VOC (0~2000ppm) Fixed VOC Gas Detector has a detection concentration range of 0~2000ppm and a resolution of 0.01ppm. ES10B11-VOC has an acousto-optic alarm and an instrument display.

EYESKY ES10B11-VOC(0~2000ppm) Stationary VOC Detector SPEC

EYESKY ES10B11-VOC(0~2000ppm) Stationary VOC Detector Details

EYESKY ES10B11-VOC(0~2000ppm) Stationary VOC Detector Packing list

SKU
NB009212
Detect gas
VOC、TVOC
Detection principle
PID photoion
Detection method
Fixed online long-term continuous detection, diffusion detection method; fixed online continuous detection, through the external air pump, to achieve pump suction flow detection method (air pump optional);
range
0~2000ppm
resolution
0.01ppm
Accuracy
≤ +/- 2% (Actual concentration, higher Accuracy required according to Sensors performance)
Operation mode
Infrared remote control for remote and close operation, easy to set up
Repeatability
≤±0.5%
Zero drift
≤ +/- 1% (F. S/year)
Response time
≤15s(T90)
recovery time
≤ 20 seconds
Explosion-proof sign
Exd II CT6
Protection level
IP66
main material
Shell: ADC12 aluminum alloy, strong, wear-resistant and corrosion-resistant (optional 316 stainless steel shell); Air chamber: high-strength wear-resistant and corrosion-resistant Aluminum profile, durable (optional 316 stainless steel air chamber)
Installation method
Wall-mounted pipe integrated type (pipe type external thread specification: M45X1.5mm, optional pipe transfer screw joint, can be welded)
Operating temperature
-30~60℃
Relative Humidity
≤ 95% RH, no condensation (Humidity > 90% RH, condensation can be equipped with Filter)
Relative Humidity
10%~95%RH
Power Supply
24VDC (Normal Operating Voltage range 12~ 30VDC)
power consumption
1.5W
Working pressure
≤200Kpa
Dimension
180*140*92mm
Weight
About 1.6Kg
execution standard
GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010
ES10B11-VOC(0~2000ppm)
Stationary VOC Detector
EYESKY ES10B11-VOC (0~2000ppm) Fixed VOC Gas Detector Picture

Introduction

Visionless ES10B11-VOC(0~2000ppm) fixed VOC Gas Detector is a new one created by Visionless Technology on the basis of ES10AGas Detector, using original imported sensors and new ones32-bit low-power processor; Dashboard display boundarysurface, the value and the progress bar are displayed at the same time, which is beautiful and generous; Circuit adoption4 layers of wiring, against weak signals and anti-dryingDisturbance is stronger; Independent high-precision imports16-bit AD chip and signal processing algorithm to measure data accuracyHigher and more stable;4~20mA, RS485, 200~1000HZ a variety of output signals can be selected, easy to accessAlarm controllers,PLC, DCS and other control systems; Explosion-proof structures are designed to be used in a variety of hazardous industriesLocation; The products are widely used in metallurgy, petroleum and petrochemical, municipal, chemical and other industries.

Introduction of Visionless ES10B11-VOC (0~2000ppm) Fixed VOC Gas Detector

Structural diagram of visionless ES10B11-VOC (0~2000ppm) fixed VOC Gas Detector

Visionless ES10B11-VOC (0~2000ppm) fixed VOC gas detection instrument panel structure diagram

Detail diagram of Visionless ES10B11-VOC (0~2000ppm) fixed VOC Gas Detector

Visionless ES10B11-VOC (0~2000ppm) Fixed VOC Gas Detector Siren Instructions

Visionless ES10B11-VOC (0~2000ppm) fixed VOC Gas Detector sensor features

Detail diagram of the air inlet hole of the ES10B11-VOC (0~2000ppm) fixed VOC Gas Detector without vision

Visionless ES10B11-VOC (0~2000ppm) fixed VOC Gas Detector signal output selection

Visionless ES10B11-VOC (0~2000ppm) fixed VOC Gas Detector application environment

FAQ
QI want to do a test on the GB/T23984 standard, is this VOC detector okay?
A Sure
QWhat is the testing principle of the fixed VOC detector? What is the range of this model?
A Hello, the fixed VOC detector without vision adopts the principle of PID, and the test range of this model is 0~ 2000ppm.
QCan ES10B11-VOC Fixed VOC Gas detection be used in flammable and explosive environments?
A Hello, yes, the fixed VOC Gas detectors without vision have been designed with explosion-proof structure and can be applied to various dangerous workplaces.
Knowledge
Standard