SUOGUANG WRS-2U Automatic Melting point meter melting point Measurement range up to 400 ℃

SE
SUOGUANG WRS-2U automatic Melting point meter is a microcomputer automatic Melting point meter using Linearity high platinum resistance Sensors, WRS-2U automatic Melting point meter Temperature Measurement range up to 400 ℃, resolution 0.01 ℃.
$1588.00/set
PromotionLoading...
Coupon
Model:
Certificate

Suoguang WRS-2U Melting point meterSPEC

Suoguang WRS-2U Melting point meterDetails

Suoguang WRS-2U Melting point meterPacking list

SKU
NB009345
Temperature range
RT+~400℃
Temperature Resolution
0.01℃
Heating rate
0.2/0. 5/1/1 5/2/3/4/5 ℃/min
Error of indication
±0.5℃(<200℃);±0.8℃(>200℃)
Repeatability
±0.2℃(0.2℃/min);±0.3℃(1.0℃/min)
Capillary tubing size
Outer diameter: 1.4mm; Inner diameter: 1.0mm
Sample height
3mm
Interface
USB Connectable PC Display Linear dispersion
Power Supply
220±10%V 80W 50/60Hz
Dimensions
398*278*210mm
Weight
10kg
WRS-2U
Melting point meter
SUOGUANG WRS-2U Automatic Melting point meter melting point Measurement range up to 400 ℃ Picture

Introduction

In the field of organic chemistry, melting point determination is a basic means to identify the nature of substances, and it is also one of the important methods for purity determination. Suoguang WRS-2R Automatic Melting Point Apparatus plays an important role in the chemical industry and pharmaceutical research, and is the required instrument for the production of drugs, spices, dyes and other organic crystal substances.

Features

◆ Adopt thin film button, super large LCD (QVGA: 320x240) display screen and photoelectric detection technology, the whole machine is comfortable and easy to operate, automatic measurement, intuitive display advantages;

◆ It has the functions of automatic display of initial melting and final melting, automatic real-time recording of melting curve, automatic calculation of melting point average value, etc.;

◆ The temperature system adopts a platinum resistance sensor with high linearity, which improves the accuracy and reliability of the melting point;

◆ Highly integrated electronic circuit realizes fast "initial temperature" setting;

◆ Eight linear heating rates to choose from, and high-precision software temperature control algorithm make the furnace temperature more accurate and stable.

◆ The working parameters of the instrument can be stored automatically, and it has the function of automatic measurement without manual monitoring;

◆Use the capillary tube stipulated in Pharmacopoeia as the sample tube, which fully complies with the Pharmacopoeia specification.

Pictures

Suoguang WRS-2U Automatic Melting Point Apparatus Display

FAQ
QDo you have the microcomputer Melting point meter required in the JB/T6177 standard?
A This WRS-2U microcomputer Melting point meter is enough.