China

KOSON KS-30 split bar scanner for thickness and diameter measurement

The KOSON KS-30 split steel bar scanner uses the principle of electromagnetic pulse to detect the diameter of steel bars and the thickness of the protective layer. The KS-30 split steel bar scanner has two thickness ranges.
Model:
Certificate

KOSON KS-30 Split bar scannerSPEC

KOSON KS-30 Split bar scannerDetails

KOSON KS-30 Split bar scannerPacking list

SKU
NB009569
Protective layer thickness measurement (nominal) range
The first Measurement Range: 6mm~ 90mm; the second Measurement Range: 7mm~ 200mm;
Measurement range of steel bar diameter
Ф6~Ф50mm
Steel protective layer thickness Measured value MPE
Protective layer thickness first range (nominal) range 6~ 59mm :≤ +/- 1mm; 60~6 9mm :≤ +/- 2mm; 70~90mm :≤ +/- 4mm; protective layer thickness second range (nominal) range 7~ 7 9mm :≤ +/- 1mm; 80~119 mm :≤ +/- 2mm; 120~200mm :≤ +/- 4mm
Measured value MPE range
+/- 1st gear
Display
160×128mm
Normal operation Environmental requirements
Operating temperature: -10 ℃~ + 40 ℃; Relative Humidity: < 90% RH (no corrosion gas in the air; no strong electromagnetic interference;)
Power Supply
Rechargeable battery with a Power Supply time of up to 50 hours
Host size
220×165×90mm
Probe Volume
105×55×30mm
KS-30
Split bar scanner
KOSON KS-30 split bar scanner for thickness and diameter measurement Picture

Detection principle

KOSON KS-30 split steel bar scanner adopts the electromagnetic pulse method with super anti-interference ability for non-damage detection.

Features

  • Detection of the position, distribution and direction of the reinforcement, the thickness of the protective layer and the diameter of the reinforcement in concrete structure engineering;

  • Construction quality acceptance inspection of concrete structures of buildings;

  • Detection and detection of steel bars in bridges, tunnels and other structures;

  • Detection data storage, viewing function, data transmission function.

According to the standard

Code for Acceptance of Construction Quality of Concrete Structure Engineering GB 50204-2015

Technical Standard for On-site Inspection of Concrete Structures GBT50784-2013

Technical specification for the detection of reinforcement in concrete, JGJ/T152-2008

Technical Standard for Detection of Building Structures GB/T50344-2004

"Technical specification for detecting the thickness of the protective layer and the diameter of the reinforcement by electromagnetic induction" DB11/T365-2006

"Specification for Measurement and Calibration of Reinforcement Protective Layer Thickness Measuring Instrument and Floor Thickness Measuring Instrument" JJF1224-2009

Product display diagram

KOSON KS-30 split steel bars scanner display diagram