GB/T 24417-2009 《Determination of diisononyl adipate in PVC wrap films - Gas chromatographic method》 Related products

This standard specifies the determination of diisonononyl adipate (DINA) in polyethylene gas (PVC) plastic wrap by Gas chromatography, CG, which is suitable for its determination. The detection limit of the method is 0.03 g/100 g, and the minimum limit of quantification is 0.1 g/100 g. The standard refers to a series of normative documents, including Precision of Measuring method, reagents and materials, etc. The sample preparation includes cutting the laboratory sample, mixing it evenly, and then separating 50 g for later use.