GB/T 27786-2011 《Laboratory efficacy test methods and criterions of public health equipment - Sticky tape or paper for flies》 Related products

This standard specifies the test method and evaluation criteria for the sticky trapping effect of indoor sticky fly bands (paper). It is applicable to the trapping effect test of housefly (Musca domestica). The sample should be adult insects from the 3rd to 7th day of age after feathering, regardless of gender. The test equipment includes stopwatch, counter and test cabinet with size of 700 mm × 700 mm × 700 mm. The test conditions are indoor lighting using 2 40W fluorescent lamps, the temperature is maintained at 26 ° C +/- 1 ° C, and the relative humidity is 60% +/- 5%. The standard provides scientific, systematic test methods to ensure the effectiveness and Reliability of sticky fly bands.

This summary is not the original standard text and is for reference only. For accurate information, please obtain it through official channels.
Status Active
CCS C05
ICS 11.020
Release Date 2011-12-30 00:00:00
Implementation Date 2012-07-01 00:00:00