Status
All Active Abolish Replaced Incoming Convert to industry standard
Category
Number Year
Name

GB/T 12146-2005 《Analysis of water used in boil and cooling system Determination of ammonia-Phenol method》 Related products

This standard specifies the method for the determination of ammonia content in boiler water and chilled down water, which is applicable to water samples with ammonia content between 0.061 mg/L and 4.5 mg/L. This method determines the concentration of ammonia by reacting ammonia with phenol to generate indigo blue and measuring its Absorbance. This method can effectively eliminate the interference of hydrazine, copper and iron to ensure the accuracy of the measurement results.

This summary is not the original standard text and is for reference only. For accurate information, please obtain it through official channels.
Status Active
CCS J98
ICS 13.060.25
Release Date 2005-02-06 00:00:00
Implementation Date 2005-12-01 00:00:00
Sort Filter
No information related to was found
Extended reading