GB/T 6581-2007 stipulates the use of flame emission or atomic absorption spectroscopy (AAS) to determine the resistance of Glass to muriatic acid etching at 100 ° C. Glass samples are placed in muriatic acid etching at 100 ° C to collect the etching solution. Flame emission or AtomicAbsorption Spectroscopy is used to measure the content of specific elements dissolved in the etching solution due to corrosion of Glass to evaluate the degree of corrosion resistance of Glass. Standard detailed specifications for sample preparation, etching experimental conditions, instrument operation procedures and result calculation methods ensure accurate and reliable test results, providing an important basis for mass detection of Glass products and suitability evaluation in specific environments.
| Status | Active |
|---|---|
| CCS | Y22 | ICS | 81.040.01 |
| Release Date | 2007-12-05 00:00:00 | Implementation Date | 2008-09-01 00:00:00 |