All STIP-scan
Status
All Active Abolish Replaced Incoming Convert to industry standard
Category
Number Year
Name

GB/T 8151.9-2012 《Methods for chemical analysis of zinc concentrates - Part 9: Determination of fluorine content - The ion selective electrode method》 Related products

GB/T 8151.9-2012 standard specifies a method for the determination of fluorine in zinc concentrates, using the Ion selective electrode method. This method is suitable for the analysis of zinc concentrates with fluorine content in the range of 0.050% to 0.50%. During the determination process, the sample is first melted with potassium hydroxide for analysis, and then leached and filtered with water to remove interfering elements such as iron and lead. Then, the solution acidity is adjusted and the ionic strength is adjusted using ammonium citrate. Finally, the fluorine ion selective electrode and the saturated Calomel electrode are used to measure the potential difference of fluorine to determine the fluorine content. The specifications of the required reagents and the preparation method of the standard solution are described in detail in the standard to ensure the accuracy and Reliability of the test.

This summary is not the original standard text and is for reference only. For accurate information, please obtain it through official channels.
Status Active
CCS H13
ICS 77.120.60
Release Date 2012-12-31 00:00:00
Implementation Date 2013-10-01 00:00:00
Sort Filter
Extended reading