LEICI PHSJ-3F Laboratory pH Meter Class 0.01, Potential/pH/Temperature

SE
The LEICI PHSJ-3F acid alkalinity tester has a resolution of 0.01 pH respectively, and has a reminder function of electrode performance and calibration. It is a desktop smart acidity instrument.
$435.32/set
PromotionLoading...
Coupon
Model:

LeiCi PHSJ-3F pH meterSPEC

LeiCi PHSJ-3F pH meterDetails

LeiCi PHSJ-3F pH meterPacking list

SKU
NB001113
Instrument level
Level 0.01
Measurement parameters
Potential, pH and temperature
mV range
-2000.0~2000.0mV
mV resolution
0.1mV
mV electronic unit error of indication
+/- 0.1% or +/- 0.3 mV
PH range
(-2.00~20.00)pH
pH resolution
0.01pH
An indication of pH electronic unit error
±0.01pH
Temperature range
(-5.0~110.0)℃ /(23.0-230.0)℉
Temperature resolution
0.1℃/0.1℉
Temperature electronic unit error of indication
±0.2 ℃
Power
Power adapter (input: AC100~ 240V, output: DC9V)
Dimensions
242*195*68mm
Weight
0.9kg
PHSJ-3F
pH meter
LEICI PHSJ-3F Laboratory pH Meter Class 0.01, Potential/pH/Temperature Picture

Introduction

Leici PHSJ-3F pH tester is an intelligent desktop pH meter with a measurement accuracy of 0.01 and a measurement temperature accuracy of 0.1℃. It is used in laboratories to detect the pH value of solutions and determine the quality of products. In terms of accuracy design, the PHSJ-3F pH tester adds electrode performance and calibration reminder functions to improve the accuracy of measurement. There are three reading functions: Smart, Timed, and Cont for users to choose from. In addition, the pH tester can not only measure PH value, but also temperature value and mv value. It is multi-functional and has wider applicability.

Features

1. Three reading mode functions: Smart-Read mode can intelligently determine the end point and facilitate reading; Timed-Read mode can automatically store data through timing ; Cont-Read mode allows users to clearly understand the continuous change process of the sample and achieve continuous intervals. Measurement.

2. Thundermagnetic PHSJ-3F/pH tester realizes electrode MI and calibration reminder functions, and the measurement is accurate.

3. The measurement information complies with GLP specifications and can be completely traced.

a. Set the operator number and record the operator's operation process;

b. Realize record review and print calibration data;

c. Achieve viewing, deletion, printing and storage of measurement data;

d. Measurement data can be stored up to 500 sets and complies with GLP specifications.

4. The measurement value, temperature value, measurement mode, electrode slope, equipotential value, operation time and date are displayed on the large dot matrix LCD. The content is clear and comprehensive.

5. Achieve automatic calibration, automatic temperature compensation, automatic identification of 5 buffer solutions, and can be calibrated at 1-3 points.

6. The PHSJ-3F pH tester has 3 isoelectric points to choose from, and can easily measure the PH value of pure water, boiler water, ultrapure water, etc.

7. The PC panel uses new materials and the touch digital keyboard is durable.

8. High data security and power-off protection.

9. USB communication interface and REX data acquisition software can be used.

10. Chinese operation interface and well-designed human-machine interface.



FAQ
QWhat's the difference between these 3? I think the parameters are the same.
A 3C: range -2-18ph, manual temperature compensation, 3-point calibration, 50 sets of results are stored. 3E: range -2-18ph, manual + automatic temperature compensation, 3-point calibration, 50 sets of results are stored. 3F: range -2-20PH, manual + automatic temperature compensation, 5-point calibration, 500 sets of results are stored, there is RS-232 interface to connect to PC, bilingual switching in Chinese and English
QWhy does the same sample read differently on different pH meters?
A Hello! The situation you mentioned will happen, which is caused by the different correction conditions of the two pH meters. Therefore, to eliminate this situation, as long as the two pH meters are corrected in the same buffer and at the same time, this problem can be solved.