KAIRDA NDT310 Ultrasonic Thickness Gauge Metal, Glass, Ceramic, Sheet, etc. thickness measurement 0.1/0 accuracy

SE
Measurement error +/- (1% H + 0.04) mm, Display resolution 0.1mm /0.01mm optional, using high performance, low power processor technology, through the bright LED liquid crystal display measurement data, can be widely used in the processing industry, manufacturing, metal industry, chemical industry, ceramics and other fields, accurate, reliable and stable measurement.
Model:
Certificate

KairDa NDT310 Ultrasonic Thickness GaugeSPEC

KairDa NDT310 Ultrasonic Thickness GaugeDetails

KairDa NDT310 Ultrasonic Thickness GaugePacking list

SKU
NB001268
Probe frequency
5MHz
Probe style
Split probe
Probe diameter
F4mm
Probe contact temperature
-10~60℃
Lower limit of pipe measurement
F20 * 3mm
Measurement error
±(1%H+0.04)mm
Display resolution
0.1mm /0.01mm optional
unit system
mm/inch
Storage Capacity
500 pieces
Sound speed range
1000~9999m/s
Display
LED liquid crystal display
Operating language
Chinese
Application software
without
Power
AA type alkalinity battery 1.5V (2 *)
Operating Time
250H (without backlight)
Host size
150*74*32mm
Weight
238g
Application
Film thickness measurement of plastics, Pottery and porcelain, Glass, Metals (such as Steel, Aluminum, Cast Iron, Copper, etc.), Glass Fibers and Miscellaneous Any good conductor of ultrasonic waves, and measurement of the speed of sound of the material
Optional probe
2MHz (cast iron probe), 7MHz (micro-diameter probe) (Φ15 mm × 2.0 mm), 5MHz (high temperature probe)
Probe diameter
Φ6 mm (optional) Φ10 mm (optional) Φ12 mm (optional)
Calibrating block
4.0 mm (steel)
Measurement speed
4 times/sec for single point measurement, 20 times/sec for scanning mode
Film thickness capturing capability
Yes.
NDT310
Ultrasonic Thickness Gauge
Measurement error +/- (1% H + 0.04) mm, Display resolution 0.1mm /0.01mm optional, using high performance, low power processor technology, through the bright LED liquid crystal display measurement data, can be widely used in the processing industry, manufacturing, metal industry, chemical industry, ceramics and other fields, accurate, reliable and stable measurement.
KAIRDA NDT310 Ultrasonic Thickness Gauge Metal, Glass, Ceramic, Sheet, etc. thickness measurement 0.1/0 accuracy Picture

Introduction

KAIDA NDT310 Ultrasonic Thickness Gauge adopts high-performance, low-power consumption processor technology, displays measurement data through bright LED liquid crystal, and is also very convenient for the environment measurement with insufficient light. It is an external probe type ultrasonic Thickness Gauge. It can measure the thickness of good ultrasonic conductors whose thickness ranges from 0.75mm to 300mm, and has the functions of probe zero point calibration and two point calibration. NDT310 ultrasonic Thickness Gauge can be widely used in processing industry, manufacturing industry, metal industry, chemical industry, ceramics and other fields, and the measurement is accurate, reliable and stable.

Features

1. NDT310 ultrasonic Thickness Gauge can be used with a variety of dual crystal probes with different frequencies and different chip sizes.

2. It can reversely measure the sound velocity of known thickness, so as to improve the measurement accuracy.

3. It has a coupling status prompt function.

4. The remaining power indicator function can display the remaining battery power in real time.

5. NDT310 ultrasonic Thickness Gauge has LED backlight display function, which is convenient to use in the environment with insufficient light.

6. It has power-saving functions such as automatic sleep and automatic shutdown.

7. It is small in size, easy to carry, reliable in measurement, and has the advantages of anti-shock, anti-vibration, and anti-electromagnetic interference.

Applications

1. Measuring material: NDT310 ultrasonic Thickness Gauge can measure the thickness of plastic, ceramics, glass, metal (such as steel, aluminum, cast iron, copper, etc.), glass fiber and any other good conductor of ultrasonic wave, and can measure the sound velocity of the material Measurement.

2. It is widely used for thickness measurement of various plates, boiler vessel wall thickness, pipe wall thickness, various pipes and pressure vessels, and monitors the degree of thinning after being corroded during use.

Pictures

KAIDA NDT310 Ultrasonic Thickness Gauge Display Figure 1

KAIDA NDT310 Ultrasonic Thickness Gauge Display Figure 2

KAIDA NDT310 Ultrasonic Thickness Gauge Display Figure 3

Aedas NDT310 Ultrasonic Thickness Gauge Probe Display

FAQ
QPlease suggest a thickness gauge for me, which is mainly used to measure the wall thickness of steam pipelines, about 300 degrees, and the wall thickness of elbows.
A NDT310 with high temperature probe
QCan the standard probe measurement range of NDT310 be measured for metals and non-metals?
A NDT310 Ultrasonic Thickness Gauge for Measuring Metal and PVC Pipe Wall Thickness
QMainly used to measure the wall thickness of steam pipes and elbows. Is this one okay?
A Yes, but with a high temperature probe.
QIs this the Ultrasonic Thickness Gauge mentioned in ZBN 77001?
A OK
QFilm thickness measurement of polyurethane sheet, the maximum range is 110-150mm, the parameters are required to 2 decimal places, desktop, can be connected to a computer, data transmission one-click operation Which one is more suitable?
A For foamed and porous materials, hello, ultrasonic conductors can only be measured, but this material is special, uneven and foamed may not work, and materials with high Density are required, so this material is difficult to measure. It is recommended to use a mechanical thickness gauge.
QCan your thickness gauge measure the Film thickness of thin cloth or thin sheet? Such as mesh, paper, film base and other Film thickness (Film thickness of steel mesh cloth and Film thickness of steel mesh surface coating)
A Hello, because the steel wire mesh is not uniform material and there is a gap in the middle, the error value of the test result will be very large, so it cannot be tested. If it is to test the film thickness of thin cloth or paper, you can try to put a sample on the iron sheet as an iron coating and use an ordinary thickness gauge to test, but there are certain errors!
Standard