China

BANTE A130-UK Laboratory pH Meter Acid alkalinity Detector

SE
Optional 5 ion Measuring methods, 1000 sets of data storage, system menu contains 20 optional parameters, Measurement accuracy: 0.002pH.
$626.00/set
PromotionLoading...
Coupon
Model:
Certificate

Bante A130-UK Laboratory pH MeterSPEC

Bante A130-UK Laboratory pH MeterDetails

Bante A130-UK Laboratory pH MeterPacking list

SKU
NB014763
PH range
-2.000~20.000pH
PH measurement Accuracy
±0.002pH
resolution
0.01/0.001pH/optional
Temperature Measurement range
0~100℃/32~212℉
Power
DC12V power adapter
Dimensions
240*200*80mm
Weight
1.7kg
PH calibrated
1 to 5 point
Calibrating fluid
USA, NIST, DIN, custom
mV range
-2000~2000mV
mV measurement Accuracy
±0.2mV
mV resolution
0.1mV
ORP calibrated point
1 point (only for R.mV mode)
ORP measurement mode
Relative or absolute mV
Temperature Measurement range
0~105℃/32~221℉
Temperature measurement Accuracy
±0.5℃
temperature resolution
0.1℃
Temperature calibrating point
1 point
Temperature unit
℃, ° F, optional
data lock
Manual or automatic end point locking
Data stability condition
Standard or high precision
Calibrated reminder
1 to 31 days or closed
Interval reading
10, 30, 60 seconds, 10, 30 minutes or off
One-click reset function
contain
data storage
1000 groups
Communication interface
USB
Connector
BNC
Display
7-Inch TFT LCD
Optional accessories
P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
Optional accessories
P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode
Optional accessories
TP-10K temperature probe, 501 type ORP electrode, 502 type ORP electrode, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard)
Packaging Dimensions
300*240*170mm
Encasement Weight
2kg
Ion Measurement range
0~30000Ppm, mg/L, mol/L (please refer to the ion electrode description for the actual range)
Ion measurement Accuracy
± 0.5% F. S (primary ion), ± 1% F. S (secondary ion)
Ion display resolution
0.001, 0.01, 0.1, 1
Ion calibrated point
2 to 5 point
Ion measurement mode
Direct reading method, known addition method, known reduction method, sample addition method, sample reduction method
Hardness Measurement range
0.05~200mmol/L
Hardness measurement Accuracy
±1% F.S
Water Hardness Display Resolution
0.001, 0.01, 0.1, 1
Hardness calibrated point
2 to 5 point
Water Hardness Measurement Units
° dH, ° e, ° fH, mg / L, mmol / L
Temperature compensation method
Automatic/Manual
A130-UK
Laboratory pH Meter
Optional 5 ion Measuring methods, 1000 sets of data storage, system menu contains 20 optional parameters, Measurement accuracy: 0.002pH.
BANTE A130-UK Laboratory pH Meter Acid alkalinity Detector Picture

A130 Professional LABOratory pH/Ion Meter

Professional laboratory pH Ion Meter, optional 5 ion measurement methods, 1000 sets of data storage, system menu contains 20 optional parameters, measurement accuracy: 0.002pH.

pH mode features:

• Professional laboratory pH Ion Meter with 7-inch TFT display.

• Optional pH buffer standard (USA/NIST/DIN) or 5-point custom calibration.

• Automatic electrode diagnosis, with electrode slope and offset display.

• Automatic temperature compensation to ensure accurate measurement over the full range.

• Solution Temperature Coefficient (STC), compensates for pure water measurements and converts readings to 25°C.

• Alarm limit, automatically warns if the measured value exceeds the set range.

pH Ion Meter

ORP mode features:

• 1-point offset calibration, allowing adjustment of displayed values to known standards.

• Relative and absolute mV modes provide accurate ORP readings.

Ion mode features:

• Optional ion measurement methods, including direct reading method, known addition method, known subtraction method, sample addition method and sample subtraction method.

• Optional concentration units, including ppm, mg/L, mol/L, mmol/L.

• 2 to 5-point key calibration, including 8 optional concentration calibration points.

• Automatic identification of ion-selective electrodes without specifying ion types.

• Electrode management can store the slope of 3 ion electrodes and recall the calibration data of each electrode.

• Calibration report provides calibration standards and electrode slope details.

pH Ion Meter

Water hardness mode features:

• 2 to 5 point key calibration from low to high concentration.

• Optional water hardness units, including German degrees, British degrees, French degrees, mmol/L and mg/L.

General features:

• Calibration due reminder to remind users to calibrate the meter regularly.

• Automatic end point locking, retaining stable measurement values for easy viewing and recording.

• Interval reading mode, regularly send measured values to PC or printer.

• Password protection to prevent unauthorized calibration and settings.

• Expanded memory can store up to 1000 sets of data.

• USB communication interface is easy to connect external devices.

• One key reset (Reset) automatically restores the instrument to the factory default settings.