American JENCO 6313 (set) pH oxidation reduction controller

SE
With waterproof design, LCD display, automatic temperature compensation and adjustable temperature probe, support 4~ 20mA isolation current output and two sets of settable relay control. With correction value power-off memory function, and CE certification, suitable for a variety of application fields.
Model:

JENCO 6313 (set) pH oxidation reduction controllerSPEC

JENCO 6313 (set) pH oxidation reduction controllerDetails

JENCO 6313 (set) pH oxidation reduction controllerPacking list

SKU
NB015181
PH range
-2.00~16.00pH
Measurement Accuracy
+/- 0.1% +/- 1 word
Resolution
0.01pH
Power Supply
110或230VAC,50/60Hz
Dimensions
96*96*148mm
PH standard solution
US (4.01, 7.00, 10.01) or (4.00, 6.86, 9.18) user-selected, automatic two-point correction
Data storage for pH correction
Yes.
Current output range
A set of 4~ 20mA reversible, isolated current outputs
Insulation Voltage/maximum load
1000VDC/550Ω
opening size
92*92mm
protective measures
4-Digit password protection
Relay Control Output/Maximum Load
Two sets of ON/OFF control in the system 2.5A/230VAC
Measurement range mV
-2500~2500mV
mV resolution
1mV
Measurement Accuracy of mV
±0.1%F.S
Measurement range
-10.0~120.0℃
Temperature Resolution
0.1℃
Measurement Accuracy
±0.3℃
Shop Accessories
PH electrode, ORP electrode, mounting bracket, sealing box
6313 (set)
pH oxidation reduction controller
With waterproof design, LCD display, automatic temperature compensation and adjustable temperature probe, support 4~ 20mA isolation current output and two sets of settable relay control. With correction value power-off memory function, and CE certification, suitable for a variety of application fields.
American JENCO 6313 (set) pH oxidation reduction controller Picture

Features

  1. Standard 1/4DIN waterproof body design

  2. Liquid crystal display, which can display pH (ORP) and temperature values at the same time

  3. 4~20mA reversible, with isolated current output, user-configurable

  4. Two sets of relay control, control point, hysteresis width can be set by the user

  5. Automatic temperature compensation for self-selectable temperature probe (PT1000, TH10K, BALCO3K)

  6. Correction value power-off memory function

  7. The products have passed CE certification 

  8. With IP-600-9TH (5m)


JENCO 6313 (set) pH redox controller

Optional

pH electrode

ModelIntroduction
IP-600-9THGeneral wastewater treatment (can be used below 70°C for a long time)
ST873High-temperature field (can be used below 105°C for a long time)
IP-600-1NTHGeneral wastewater treatment (can be used below 90°C for a long time)
IP-600-3CNTHPure water pH composite electrode (pure water, ultrapure water measurement)

Redox electrodes

ModelIntroduction
IR-500-8General water treatment field
IR-500-9General water treatment field

Sheath tube

ModelIntroduction
Sheath tube009A

Sealed box

ModelIntroduction
011-200-00Dial-mounted
012-200-00Wall-mounted