JENCO 3010M portable conductivity conductivity range 0.00uS~ 400.0mS

SE
0~400mS/0.01µS, salinity display 0~80ppt, TDS (with 2 ring electrodes)
Model:

JENCO 3010M Portable conductivitySPEC

JENCO 3010M Portable conductivityDetails

JENCO 3010M Portable conductivityPacking list

SKU
NB015185
Measurement range
0.00μS/cm~400.0mS/cm
Measurement error
±0.5% F.S.
Resolution
0.01uS~0.1mS
Temperature compensation range
-10.0~90.0℃
Data storage
50 sets
Power Supply
9V battery
Operating temperature
0~50℃
Operating humidity
≤90℅RH
Dimensions
186*70*37mm
Weight
260G (without battery)
Salinity range
0.0~70.0ppt
Salinity resolution
0.1ppt
Measurement Accuracy of salinity
±0.2%F.S.
Measurement range
-10.0~90.0℃
Display resolution
0.1℃
Temperature Accuracy
+/- 0.2 ℃ or 0.4% F.S. whichever is greater
Electrode constant specification
K=0.1/1.0/10.0
reference temperature
15.0~25.0 ℃ adjustable, the default value is 25.0 ℃
temperature coefficient
0.00~4.00% adjustable, the default value is 1.91%
TDS conversion factor
0.30~1.00 (default 0.65)
calibration data store
Yes.
Sound feedback
All keys
shutdown mode
Automatic shutdown
Shop Accessories
K = 0.1 Glass two-wire Conductivity Detector electrode (pure water, ultrapure water measurement), K = 10.0 Glass (outer tube plastic) two-wire Conductivity Detector electrode (high conductivity medium water measurement)
3010M
Portable conductivity
0~400mS/0.01µS, salinity display 0~80ppt, TDS (with 2 ring electrodes)
JENCO 3010M portable conductivity conductivity range 0.00uS~ 400.0mS Picture

Features

  • The 3010M measures conductivity, salinity, and temperature.

  • Automatic temperature compensation.

  • Microcomputer design, correction value power-off memory function.

  • 50 sets of measurement data memory function.

  • Low battery warning function,

  • It has an automatic shutdown function.

  • IP65 waterproof body design.

  • CMC, ROHS, CE certification.

Ren's 3010M portable conductivity

Optional
109AK=0.1 glass two-wire conductivity electrode (pure water, ultrapure water measurement)
107AK=10.0 glass (outer tube plastic) two-wire conductivity electrode (high conductivity medium water measurement)


FAQ
QDoes this portable conductivity meet the JB/T6855 standard?
A The portable conductivity is suitable for JB/T6855, please consult customer service for detailed application definition
QHow to correct the 3010M Portable Conductivity detector?
A (1) Conductivity detector electrode cleaning, into the known Conductivity detector standard solution The choice of quasi-solution is better based on the range of the measured solution Conductivity detector values. Put the electrode Immerse in a standard solution (at least 2 to 3 inches or 5 to 7 centimeters) and stir slightly to The air bubbles on the electrode piece are eliminated. (2) Wait a moment for the temperature to stabilize. During this period, the host displays the "rAGE" table It shows that the host is automatically grabbing the measurement range, which is normal. When the temperature stabilizes, You can use the up and down buttons to adjust this standard Conductivity detector value (25 ° C), press "ENTER" key to confirm. When the host beeps, it means that the correction steps have been taken. Successful completion, the host automatically returns to measurement mode.
QWhat does it mean to show "over" in a test?
A Conductivity detector value exceeds 400.0mS. (K = 10.0) ● Conductivity detector value exceeds 40.0mS. (K = 1.0) ● Conductivity detector value exceeds 400.0uS. (K = 0.1) ● Salinity value exceeds 70.0ppt. The electrode needs to be immersed in the standard solution or the tested solution at least 2~ 3 inches or 5~ 7cm. ● Have enough time to wait for the electrode reading to stabilize. ● Recalibrate with the standard solution. ● Replace the standard solution. ● Clean the Conductivity detector electrode.