YUE FENG 723N visible Spectrophotometer with USB interface and PC software
SE
Using Czerny-Turner optical path to ensure linear Precision and ultra-low stray light, Light spectrum Bandwidth 4.0nm, Wavelength Precision +/- 1.0nm, spacious sample chamber can accommodate 5~ 100mm Colorimetric dish, support Automatic calibration and Data storage.
YUEFENG 723N(PC) Visible Spectrophotometer Packing list
SKU
NB017242
Optical inspection system
Aberration (1200L/mm Grating)
Light spectrum Bandwidth
4.0nm
Wavelength range
325~1100nm
Wavelength Precision
±1.0nm
Wavelength Repeatability
≤0.5nm
Photometric Range
0~200%T、-0.301~3.000A、0~9999C
Photometric Precision
±0.002A(0~0.5A)、±0.003A(0.5~1A)、±0.5%T
Luminosity Repeatability
≤0.2%T(0~100%T);0.001A(0~0.5A);0.002A(0.5~1A)
stray light
≤0.1%T@360nm
Noise level
100%≤0.15%T;0%≤0.1%T
Baseline flatness
±0.002A
Interface
USB interface and PC software
printout
Parallel entrance
Light source
Tungsten halogen lamp
Dimension
450*340*180mm
Weight
12kg
drift
≤0.001A/h@500nm
scanning speed
Fast, medium, slow.
723N(PC)
Visible Spectrophotometer
Using Czerny-Turner optical path to ensure linear Precision and ultra-low stray light, Light spectrum Bandwidth 4.0nm, Wavelength Precision +/- 1.0nm, spacious sample chamber can accommodate 5~ 100mm Colorimetric dish, support Automatic calibration and Data storage.
The spacious sample room can accommodate 5 ~ 100mm cuvette.
The host can perform photometric detection, quantitative detection, and can display standard curves, and can store 100 standard curves and 200 detection data.
With wavelength automatic calibration, automatic power off to keep data.
The main components adopt imported configuration, which is convenient for maintenance.
The newly designed Czerny-Turner optical path ensures the accuracy of detection linearity and ultra-low stray light.
Can be directly connected to a printer (optional) to print data or maps.
Main functions of the instrument
Photometry
The test of absorbance, transmittance and concentration at a fixed wavelength.
quantitative test
a. Standard curve method: Up to nine standard curves can be established, and the graph and regression equation can be displayed.
b. Coefficient method: use the formula C=KA+B, A=KC+B, and pass the input correlation coefficient test.
System functions
Wavelength calibration, dark current calibration...
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
QMeet GB/T1721 visible spectrophotometer
A
723N (PC) visible spectrophotometer, please refer to it.