United Kingdom

UK ION SCIENCE FALCO FAL-3000P Fixed VOC Online Monitor, Pump Suction

The UK Ion ION SCIENCE FAL-3000P fixed VOC online monitor is an EX d certified VOC online monitor with a detection range of 0-3000ppm and a resolution of 1ppm. The FAL-3000P has special typhoon technology to prevent the instrument from condensing.
Model:
Certificate

Ion Science FAL-3000P Fixed VOC online monitorSPEC

Ion Science FAL-3000P Fixed VOC online monitorDetails

Ion Science FAL-3000P Fixed VOC online monitorPacking list

SKU
NB018423
Sampling method
Pump suction
Detection principle
PID
range
3000ppm
resolution
1ppm
Response time
≤30s(T90)
user interface
OLED display: high contrast ratio, black background and white text 128x64px; Screen size: 35x17.5mm; 5 magnetic switches with LED confirmation lights (up, down, left, right, confirmation), with exciter
status indicator
Bright and visible status indicators: red, orange, and green
certification
Ex II 2G Ex d ib IIC T4 Gb。ISO9001:2008
Operating temperature
-20℃~60℃
Operating humidity
0~100% Relative Humidity and Humidity
Mechanical interface
2 cable access points with 3/4 "NPT threads (left and right); 2 3/4" NPT threads for M20 stainless steel (configured)
Dimension
290*190*125mm
Installation point
2 M8
Input Power
Operating Voltage: 12~ 40Vdc; Maximum Power: 7W
output
4~ 20mA (active and passive); RS485 supports Modbus protocol; configurable relays and 2 SPST switches
FAL-3000P
Fixed VOC online monitor
UK ION SCIENCE FALCO FAL-3000P Fixed VOC Online Monitor, Pump Suction Picture

Introduction

FALCO Falco fixed VOC online monitor, designed for extreme meteorological conditions and certified for EX d flameproofing, is a satisfactory safety equipment for typical high-risk places of volatile organic gases in the manufacturing and processing industries, and can continuously detect total volatile organic gases.

 FALCOPossession of Typhoon technology (Typhoon Technology) can prevent the inside of the instrumentPIDThe Detector forms condensation, and the instrument can operate in condensate environments and in harsh weather. InstrumentalPIDSensors appliedIONGrid electrode technology to reduce reading drift and downtime. Standard on all modelsRS485 [Modbus®]4-20mAand relay outputs, configurable for high-low output alarms, fault conditions, or test cycle synchronization, plus the instrument's multi-color status display can be viewed from sunlight20The alarm status can be seen clearly from meters away, so it can be realized in the Operating EnvironmentVOCSecurity alarms.

 FALCOPump-suction or diffusion options are available, and each has four detection ranges0-10ppm0-50ppm0-1000ppm0-3000ppm。 For locations where measurement is difficult to access, the pump-suction type is the perfect choice; The diffusion type, on the other hand, has very low maintenance costs and does not require maintenance on the pump.

Features

Very good sensor performance, reducing reading drift and downtime

The instruments are available in either suction or diffusion version

For hard-to-access locations, the pump-suction type is the perfect choice

Diffusion sampling reduces contamination in the testing chamber and reduces maintenance costs

Four detection ranges are available

Calibration coefficients can be selected according to different VOC gases

RS485 [Modbus®], 4-20mA and relay output are standard

safe

Intrinsically safe, the instrument is Exd flameproof certified

Accurate results in all environmental conditions

Rugged design for use in harsh environments

The typical lifespan of a high-quality PID detection lamp is up to 2 years

The multi-color status display allows the alarm status to be seen from up to 20 meters away in sunlight

Ion Science FAL-3000P fixed VOC online monitor display diagram