DONGRU DR370 galvanized Thickness Gauge is simpler for measurement of nonmagnetic metal substrates such as Aluminum Panels

SE
EDDY Current coating thickness measurement, thickness measurement range 0~1250μm, error +/- 3%, black plastic shell, split NF probe, large LCD display, suitable for Aluminum Panel and other nonmagnetic metal substrate measurement.
Model:

DongRu DR370 Coating Thickness GaugeSPEC

DongRu DR370 Coating Thickness GaugeDetails

DongRu DR370 Coating Thickness GaugePacking list

SKU
NB000212
Measurement principle
Eddy Current
Measurement range
0 ~ 1250µm
margin of error
±3%
Resolution
0.1mm | 1mm
Minimum radius of curvature
Convex 5mm; Concave 25mm
thinnest matrix
0.3mm
probe
NF Split Probe
Statistical function
Average, MAX Maximum, MIN Minimum, Number of Tests
icon function
without
Power
3 * AAA alkaline battery
Calibrated Certificate
without
Language
Chinese
Display screen
LCD
supporting software
without
Total Weight
100g
Complete-built unit size
130*70*24mm
Operating temperature
0~50℃
Minimum measurement surface
10*8mm
Relative Humidity
20~90%RH
DR370
Coating Thickness Gauge
EDDY Current coating thickness measurement, thickness measurement range 0~1250μm, error +/- 3%, black plastic shell, split NF probe, large LCD display, suitable for Aluminum Panel and other nonmagnetic metal substrate measurement.
DONGRU DR370 galvanized Thickness Gauge is simpler for measurement of nonmagnetic metal substrates such as Aluminum Panels Picture

Coating Thickness Gauge Selection Tool

Introduction

Dongru DR370 Coating Thickness Gauge, a black plastic shell, split probe type, eddy current Thickness Gauge using the principle of eddy current thickness measurement. The measurement range of the DR370 coating Thickness Gauge is 0~1250 microns, suitable for use in environments with a temperature of 0~50°C and a humidity range of 20%RH~90%RH. The measurement resolution is 0.1μm/1μm, suitable for The thinnest substrate measured was 0.3mm.

Dongru DR370 Coating Thickness Gauge is a coating Thickness Gauge with a large LCD display, which makes measurement easier and counting more convenient. DR370 coating Thickness Gauge is suitable for measuring non-magnetic metal substrates such as aluminum plates.

Special feature

DR370 coating Thickness Gauge is easy to use, easy to carry, super large LCD, large font size, backlight direct reading is clearer, imported high-quality metal measuring head, precise and firm structure, better repeatability, and excellent performance.

Standards

DR370 Coating Thickness Gauge is an eddy current Thickness Gauge. According to the national industry standard GB/T 4957-1985, the eddy current thickness measurement method is used to measure non-magnetic metal substrates (such as: aluminum, copper, stainless steel) non-destructively. Thickness of conductive coating (such as paint, powder, plastic, rubber, enamel, enamel, electrophoresis, anti-corrosion layer, etc.)

product advantages

Intelligent reminder operation, convenient and accurate:Real shot of DR370 coating Thickness Gauge

The aluminum plate coating Thickness Gauge is marked with a buzzer during operation (single measurement mode)

Automatic identification of ferrous and non-ferrous substrates.

Metric and imperial conversion μm/Mil

low Voltage indication

Manual/automatic shutdown function

Beautiful appearance design:

DR370 Coating Thickness Gauge is simple and elegant, portable, exquisite in appearance, fine in workmanship and accurate in measurement

Fully intelligent touch buttons, non-slip type, unique design, novelty, user-friendly, compact structure, professional technology

Imported high-quality metal measuring head is adopted, with more stable performance, wear resistance and pressure resistance, and long service life

Simple and readable test operation:

Large LCD display, backlight, large font size display, highly clear and accurate readings from any angle

The test speed is fast, the sensitivity is high, and the stability is good.

Two modes of continuous test and single measurement are optional; continuous test can effectively reduce human error and make the measured value more accurate.

The DR370 coating Thickness Gauge can count the maximum value, minimum value, average value, and measurement times. It can be completed with one key, good, effective, convenient and large-capacity storage, can store more than 800 measurement data, connect to the computer to read the data and print and save .

Two calibration methods can be used: zero-point calibration and two-point calibration, two-point calibration is more accurate.

Still worrying about measuring coating thickness, this coating Thickness Gauge can meet your needs!


FAQ
QWhich national industry standard does it meet?
A DR370 Coating thickness gauge conforms to the national industry standard GB/T 4957-1985, using eddy current thickness measurement method.
QMeasurement range of DR370 Coating thickness gauge?
A 0~ 1250 microns
QWhat are the features of DR370 Coating thickness gauge?
A This thickness gauge is easy to use, easy to carry, with large LCD screen, large font size, backlight direct reading, using imported good metal probe, precise and firm structure, Repeatability.
QWhat Calibration methods are available?
A It can be zero-point calibrated and two-point calibrated in two ways, where two-point calibrated is more accurate.
QHow to perform Aluminum Panel Coating thickness measurement?
A The operation process is marked by a beep, you can choose a single measurement or continuous test mode, the probe is vertical and quickly pressed to the Aluminum Panel coating, Measured value will be displayed on the large LCD screen.
QIs there any Coating thickness gauge that can test the coating thickness of about 2500 microns?
A Hello, you can choose the customized version of DR370, and you can customize the 3000 micron film Film thickness.
QIs this Coating thickness gauge ASTME376 compliant?
A Coating thickness gauge applies to ASTME376, please consult customer service for detailed application definition