China

MODERNER XD-1JQ-F1 1m3 formaldehyde release determination Climate Chamber, top matching type

MODERNER XD-1JQ-F1 formaldehyde release measurement Climate Chamber temperature control range is + 20 ℃~ + 35 ℃, background formaldehyde mass concentration ≤ 0.006mg/m3, XD-1JQ-F1 is a test material can determine the environment variables VOC release and release characteristics of the influence of formaldehyde release measurement Climate Chamber.
Model:
Certificate

Moderner XD-1JQ-F1 Determination of formaldehyde release climate chamberSPEC

Moderner XD-1JQ-F1 Determination of formaldehyde release climate chamberDetails

Moderner XD-1JQ-F1 Determination of formaldehyde release climate chamberPacking list

SKU
NB022851
Temperature range
20~35℃
Humidity control range
40~60% R.H.
Temperature Fluctuation
±1℃
Temperature Uniformity
≤2℃
Temperature deviation
≤±2.0℃
Humidity stability
-2%RH,﹢3%RH
Humidity Deviation
≤±3.0%RH
wind speed
The wind speed at the geometric center point in the box is 0.1~ 0.5m/s. (Wind speed is adjustable)
noise
Less than or equal to 55 decibels (A sound level), there will be no resonance sound between the box door and the equipment door
Background concentration
≤0.006mg/m3
Interior size
内箱Size1±0.02 m3;W960mm*H1050mm*D1000 mm
Temperature Resolution
0.1℃
Humidity resolution
0.1%RH
air exchange rate
0.5~ 2 times/hour (adjustable); Flow rate adjustment range should be greater than 0.25~ 2.5m3/h;
Flow rate Accuracy
Digital Flow rate meter, Accuracy 0.5; 0~500L/min Glass rotor Flow rate meter, Accuracy not less than 2.5; 0.25~ 2.5m3/h
Flow rate display
Standard Glass Rotor Flow rate meter scale display (Flow rate range adjustable) _ Analog digital micro Gas flow rate meter, Touch screen Online Flow rate display (Flow rate range adjustable)
Air tightness
When the pressure is over 1000pa, the leakage is less than 10-3 × 1m3/min; the gas flow rate difference between the import and export of the gas is less than 1%; the air pressure monitoring in the box, analog digital display micro pressure Sensors, touch screen online pressure display in the box
Stabilization time
Temperature Stabilization time is less than 40min; Humidity Stabilization time is less than 70min, the equipment can run continuously for not less than 30 days;
XD-1JQ-F1
Determination of formaldehyde release climate chamber
MODERNER XD-1JQ-F1 1m3 formaldehyde release determination Climate Chamber, top matching type Picture

Overview

  The environmental chamber can realistically simulate environmental parameters such as temperature, humidity, ventilation frequency, and air flow rate on the surface of the pattern. Through the analysis and verification of the test data results, the amount of volatile toxic and harmful (VOC) substances contained in the pattern material can be measured and calculated. The impact of its release characteristics on the environment can in turn:

ØDetermine the impact of environmental variables on the VOC release amount and release characteristics of test materials

ØClassify materials according to their VOC release characteristics

ØDevelopment of sample materials and verification of indoor air VOC release pollution characteristics

ØThe VOC release amount of the sample

ØAssessment of indoor air quality will be predicted based on detection data analysis

fulfill the standard

GB18580-2017 "Limits of Formaldehyde Release in Interior Decoration Materials - Artificial Panels and Their Products"

GB18584-2001 "Limits of Hazardous Substances in Wood Furniture, Interior Decoration Materials" (Draft for Approval)

Appendix A (Normative Appendix) in GB18587-2001 "Indoor Decoration Materials - Carpets, Carpet Pads and Carpet Adhesives - Release Limits of Hazardous Substances": Small Environmental Test Chamber Method.

GB/T 31107-2014 "General Technical Conditions for Climate Chambers for Detection of Volatile Organic Compounds in Furniture"

LY/T1980-2011 "Volatile organic compounds and formaldehyde release detection box"

LY/T1981-2011 "Formaldehyde Release Gas Analysis Detection Box"

ASTM D 6007-02 "Standard Test Method for Determination of Formaldehyde Concentration in Gas Released from Wood Products in a Small Environmental Chamber"

EN 717-1 2004 "Wooden-based panels - Test determination of formaldehyde release - Part 1: Determination of formaldehyde release using a Test Chamber"

ISO 12460-1.2007 "Determination of Formaldehyde Emission from Boards by 1m3 Climate Chamber Method" American Standard

ISO 16000-9-2006 "Determination of volatile organic compounds released from building products and furniture - Laboratory release method"

Related test reports

Background test report

Background test report

Temperature and humidity measurement test report

Temperature and humidity measurement test report

Product details


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard