JENCO 3671N (set) online pH oxidation reduction controller
SE
JENCO3671N (set) online pH oxidation reduction controller is a pH oxidation reduction controller with automatic temperature compensation function. The measurement range, measurement accuracy and resolution of the 3671N (set) pH oxidation reduction controller are 0~14.0 pH, 0.1 +/- 1 digit, 0.1 pH.
Price: Please contact customer service
Stock:
Service:
The delivery and service By NBchao.Com
SKU
NB002974
PH range
0~14.0pH
PH Measurement Accuracy
±0.1PH
Resolution
0.1pH
Impedance
Greater than 10 ^ 12 ohms
Power Supply
115/230 VAC ±15%,50/60 Hz
Dimensions
96*48*172mm
Weight
0.69 kg
Measurement range mV
-1990~1990mV
mV resolution
10mV
Measurement Accuracy of mV
±0.1% ±1 digit
Measurement range
0~100℃
Temperature Resolution
1℃
Measurement Accuracy
1 ±1 digit
Recorder, output (ph)
1400 mV
Recorder, output (mV)
-1990 ~ 1990 mV
Recorder, output (temperature)
1000 mV
Two-point on/off control
pH or ORP (user selectable)
Idle zone (dead band, no sensing zone)
+/- 0.1 pH (per set point)
Relay, output
8a at 115 VAC,4a at 230 VAC
read display
0.5 "active, red LED display
3671N (set)
pH oxidation controller
JENCO 3671N In-Line pH Redox Controller Features Standard 1/8DIN aluminium body design
The LED display can display the pH (ORP) value, and the temperature value can be displayed by the temperature switch button
Two sets of pH (ORP) relay control
It has the function of automatic temperature compensation
Power-off correction value memory function
It is an affordable industrial in-line acidity/redox controller
With IP-600-10 (20 meters)
Optional Model Introduction IP-600-9PT General water treatment (can be used below 70°C for a long time) IP-600-1NPT General water treatment (can be used below 90°C for a long time) IP-600-3CNPT Pure water pH composite electrode (pure water and ultrapure water can be used below 60°C for a long time) IP-600-10 General water treatment (use at room temperature) IP-600-1N General water treatment (use at room temperature) IP-600-3CN Pure water pH composite electrode (used at room temperature for pure water and ultrapure water measurement)
Redox electrodes Model Introduction IR-500-8 General water treatment field IR-500-9 General water treatment field
Sheath tube Model Introduction 009A 1 meter tube length
Sealed box Model Introduction 011-200-00 Dial-mounted 012-200-00 Wall-mounted
Packing list:Host X1, with IP-600-10 (20 meters) X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.