China

LABTOP iCoolero-2006 + external circulation thermostatic circulator

LABTOP high-low temperature thermostatic circulator iCoolero-2006 + is an external circulation thermostatic circulator, Temperature range -20~100 ℃, using TFT LCD screen, iCoolero-2006 + filling volume of 4.5L, with programmable control.
Certificate

labtop iCooler-2006+  External circulation high-low temperature thermostatic circulatorSPEC

labtop iCooler-2006+  External circulation high-low temperature thermostatic circulatorDetails

labtop iCooler-2006+  External circulation high-low temperature thermostatic circulatorPacking list

SKU
NB030831
Instrument type
Chilled down liquid circulation device
Protection level
I/NFL
Protection level
IP20
Temperature range
-20~100℃
Temperature Fluctuation
0.05K
Temperature Display mode
TFT
Temperature Control mode
Smart PID
Temperature sensor
Pt100
Temperature sensor
without
Heating power
1500W
refrigerant
R404a
Cooling Capacity 10 ℃
700W
Pump type
Pressure/suction pump
Pump adjustability
without
Maximum pump pressure
0.3bar
Maximum suction of pump
0.2bar
Flow rate of pump
22L/min
Pump connection interface
ID=8
Tank Volume
4.5L
Dimensions
220*420*495mm
Temperature Resolution
0.01℃
Light alarm
Yes.
audible alarm
Yes.
Temperature overrun alarm
Yes.
The temperature is not enough alarm
without
secondary protection
without
Low level protection
without
Calibrating options
Yes.
Allow continuous operation
100%
Environmental temperature
5~32℃
Allowable Relative Humidity
80%
RS232 interface
optional
USB port
optional
Power supply Voltage
200~230VAC/50Hz
Instrument noise
≤55db
Technical parameter standard
DIN 12876
iCooler-2006+ 
External circulation high-low temperature thermostatic circulator
LABTOP iCoolero-2006 + external circulation thermostatic circulator Picture

The external circulation high-low temperature constant temperature circulator products provide an economical and environmentally friendly high-low temperature constant temperature circulation solution for the laboratory. The compact design makes it quite small and very quiet to work with, and the small ones can be used directly on the table and in the fume window, and the large ones have a very small footprint. There are three types of temperature control modes for external circulation: internal control, sample control, and tracking setting control, and users can control the temperature of the tank, the temperature of external materials, and the slope according to the different temperature control methods. The program control type can also carry out 30 stages of program control, and it is very convenient for users to set the program to achieve multi-stage control such as temperature rise, constant temperature, and cooling. It is especially suitable for temperature control of glass reactors, metal reactor jackets and internal materials of reactors, as well as any application where external needs require constant temperature control.

Detail Figure 1 of the iCooler-4009P External Circulation High and Low Temperature Thermostatic Circulator

Features

1. Touch screen TFT display, touch operation, small size;

2. Proportional refrigeration and PID control technology are combined, CIT technology can directly cool down even at high temperatures.

3. Maintenance-free pressure/suction pump, resistant to fiber and metal particle matter, long life, pump pressure and flow automatically adapt to external load, effectively protect the damage of external equipment, especially glass parts;

4. Programmable control, 30 programs can be edited to achieve liquid temperature rise, cooling, constant temperature and other combination control (optional)

5. Sealed Water Tank with intuitive liquid level window, which is convenient for users to observe the liquid level, and the Water Tank is equipped with a protective overflow port to prevent accidents;

6. Stable and reliable system: high-performance and high-quality spare parts, stable quality and reliable performance.

7. Multiple safety protection: water shortage protection, temperature protection, water pressure protection, overheating and overcurrent protection, light and sound can be reminded at the same time when alarming.

8. When the alarm is alarmed, the light and sound are reminded at the same time, the buzzer can be set to silent or sound, and various alarm codes are directly displayed, and the error point can be directly determined

9. Internal and external Pt100 temperature sensor, single point and two point temperature calibration, can control the temperature of external materials

10. A variety of operation modes are optional, and the unexpected power failure can be automatically restored, which can ensure the continuous supply of cooling circulating water.

11. Optional intelligent control function: a variety of interfaces (RS485, RS232), can remotely control the start/stop of the machine through the input of 0-10V or 4-20mA analog signal.

12. Environmentally friendly refrigerant, no toxic pollution;

13. The maximum temperature and minimum temperature settings of the machine can be limited

Serial models

ModelTemperature rangeCooling capacityheatingvolume
iCooler-2003+-20~10045015003
iCooler-2006+-20~10070015004.5
iCooler-4006+-40~10080015004.5
iCooler-2009+-20~100120015009
iCooler-4009+-40~100150020009
iCooler-2017+-20~1002400300017
iCooler-2003P-20~10045015003
iCooler-2006P-20~10070015006
iCooler-4006P-40~10080015006
iCooler-2009P-20~100120015009
iCooler-4009P-40~100150020009
Unit: °C/W/L


FAQ
QWhat is the difference between Icooler circulators and Miscellaneous circulators?
A Adopting proportional refrigeration technology, which is equivalent to compressor frequency conversion function, high temperature control accuracy while saving energy and reducing consumption; pressure/suction pump Stir evenly on the liquid in the water tank, can support closed external circulation, can also support open external circulation, resistant to metal and Non-metallic impurities, maintenance-free, long life; and high temperature control accuracy, one machine multi-purpose: in addition to the cooling function chill down external equipment, LABTOP icooler products can also be used as Thermostat due to high temperature control accuracy; at the same time, the temperature range is wide, easy to configure the heater, so that the temperature range expands to one hundred degrees or even higher; compact size, saves a lot of space for the laboratory
QIs this the thermostatic circulator mentioned in JB/T5376?
A OK
QWhat is the low temperature limit of this iCoolero-2006 + high and low temperature thermostatic circulator?
A LABTOP iCoolero-2006 + meets the Temperature range of -20 to 100 ° C, with a minimum temperature of -20 ° C.
Knowledge
Standard